6. To make vertical adjustments, adjust the 2.5 mm hex screw labeled V FOLD (B in the image in
step 6).
7. To continue to refine the fold mirror adjustment, repeat the horizontal and vertical
adjustments.
8. Once satisfied with the alignment, increase the projector power.
Optimizing the integrator focus
Optimize the light focus on the DMDs.
1. Set the projector to less than 30% brightness.
2. From the Test Pattern menu, select the Integrator Rod test pattern.
3. Loosen the six screws securing the top cover.
Two screws are located at the front of the projector and four screws are located at the rear of
the projector.
Installation and setup
Christie M RGB Series Installation and Setup Guide