Service setups
HS Series D13 Service Manual
25
020-000892-03 Rev. 1 (12-2019)
1. On the IR remote keypad, press
Menu
and select
Size & Position > Size Presets > Full
Size
.
2. Enter
Factory mode
.
See
3. Select
ADC Calibration > Help
.
After a few seconds, the ADC calibration status changes from
Doing
to
Done
.
Adjusting the ROD assembly
Avoid over-adjusting the ROD to prevent damage.
1. Remove the top cover.
2. To power on with the top cover removed, firmly hold the interlock switch on the left-side cover.
3. Project an image of 100 inch in a dark environment (< 2 Lux).
4. Enter
Service mode
.
See
5. Click
Test Pattern
,
select the
White Screen
test pattern.
2
Test signal
D13HD-HS: Analog 1920 x 1080 @60Hz
D13WU-HS: Analog 1920 x 1200 @60Hz
3
Test pattern
SMPTE BAR
4
Inspection items
Check if the ADC calibration status has changed from
Doing
to
Done
.
Warning!
If not avoided, the following could result in death or serious injury.
• Do not look into the projector lens when the laser is on. The bright light may result in permanent
eye damage.
• This projector has a built-in Class 4 laser module. Never attempt to operate the projector without
all covers properly installed, unless instructed to do so in this manual for service.
ID
Part name
Description
Содержание D13HD-HS
Страница 1: ...HS Series D13WU HS D13HD HS Service Manual 020 000892 03...
Страница 112: ......