Service setups
HS Series D13 Service Manual
23
020-000892-03 Rev. 1 (12-2019)
1. Remove the top cover.
2. To power on with the top cover removed, firmly hold the interlock switch on the left cover.
3. On the
IR remote keypad, press
Menu
.
4. To execute the light sensor calibration, select
4. Light source
>
5. Light sensor
>
Yes
.
After the calibration has completed successfully, the display shows
Light sensor calibration has
been done
.
5. If the display shows
Light sensor calibration fail
, adjust the ABC adjustment gear using a
M4
socket driver
as indicated by the arrow.
6. Run the light sensor calibration again until the display shows
Light sensor calibration has been
done
.
7. After completing the adjustment, tighten the screw on the side of the gear as indicated by the
arrow.
Calibrating the lens
Always perform a lens calibration after repairing the main board or replacing the light engine.
1. Place the projector on a clean horizontal surface.
2. On the IR remote keypad, press
Menu
and select
Configuration > Lens Setting
.
3. Select
Lens Calibration
.
4. Press
Enter
.
Warning!
If not avoided, the following could result in death or serious injury.
• Do not stare into beam when the projector is on. The bright light may result in permanent eye
damage.
ID
Part name
Description
1
Inspection item
Check if the lens shift is moving smoothly.
2
Criteria
The lens shift is moving smoothly.
The screw
ABC adjustment gear
Содержание D13HD-HS
Страница 1: ...HS Series D13WU HS D13HD HS Service Manual 020 000892 03...
Страница 112: ......