Service setups
HS Series D13 Service Manual
24
020-000892-03 Rev. 1 (12-2019)
Analog digital convert calibration
If the color appears abnormal after upgrading the scalar firmware, perform an analog digital convert
(ADC) calibration.
Performing a PC calibration
To perform the PC calibration, complete the steps below.
1. On the IR remote keypad, press
Menu
and select
Size & Position > Size Presets > Full
Size
.
2. Enter
Factory mode
.
See
3. Select
ADC Calibration > Help
.
After a few seconds, the ADC calibration status changes from
Doing
to
Done
.
Performing a video calibration
To perform the video calibration, complete the steps below.
Warning!
If not avoided, the following could result in death or serious injury.
• Do not stare into beam when the projector is on. The bright light may result in permanent eye
damage.
ID
Part name
Description
1
Test equipment
Video generator (output level: 700 mv)
2
Test signal
Timing: 800 x 600 @60Hz
3
Test pattern
16 Gray
4
Inspection item
Check if the ADC calibration status has changed from
Doing
to
Done
.
ID
Part name
Description
1
Test equipment
Video generator (output level: 700 mv)