Service setups
HS Series D13 Service Manual
21
020-000892-03 Rev. 1 (12-2019)
PC mode
When performing a functional test, to optimize the image before testing, adjust the zoom and focus.
• D13HD-HS: Analog 1920 x 1080 @60Hz
• D13WU-HS: Analog 1920 x 1200 @60Hz
Frequency and tracking boundary
Adjusting the frequency and tracking boundary
To perform the frequency and tracking boundary adjustment, complete the steps below.
1. If the image is not sharp, re-adjust using the following steps:
a. Select
Menu > Size & Position > Size Presets > Full Size
.
b. Select
Menu > Input Switching & PIP > Timing Detection Mode > OFF
.
c. Select
Menu > Size & Position > Pixel Track
.
d. Use the right and left arrow keys to minimize video flicker.
2. Select
Menu > Size & Position
.
Network test
x
x
HDBaseT
function test
x
Warning!
If not avoided, the following could result in death or serious injury.
• Do not stare into beam when the projector is on. The bright light may result in permanent eye
damage.
ID
Part name
Description
1
Test equipment
Video generator
2
Test pattern
General-1 or Master
3
Inspection items
Eliminate visual wavy noise by adjusting the Resync Frequency or Tracking.
• Check if noise exists on the screen.
• Adjust the horizontal and vertical position of the video to fit the screen
frame.
4
Criteria
• If noise is on the screen, to adjust the phase, press
Menu > Size &
Position > Pixel Phase
.
• PC mode must includes supported formats with frequency and auto
detection.
Update
Parts replaced
Main
board
I/O
board
Lan
board
Color
wheel
Firmware DMD
board
DMD Light
engine
Combiner