Parts and Module Replacement
CP42LH Service Manual
60
020-101686-03 Rev. 1 (08-2016)
8. Wearing the gloves provided with the service kit, pull the integrator assembly toward the lens
element and lift it up and out of the projector.
9. Set the integrator assembly in a clean area where it cannot be damaged.
10. Recreate your Measured Color Gamut Data (MCGD) files. See the user manual for instructions.
Fold mirror access panel
The fold mirror access panel is located underneath the front section of the projector.
Estimated replacement time: 15 m 30 minutes for calibration
1. Open the
2. Disconnect the P14 connector.
3. Pull the harness through the cable retaining clips to allow movement of the harness.
4. Remove the screw securing the retaining clip.
5. Remove the 4 screws securing the fold mirror access panel.
6. Disconnect the color sensor connector.
7. Remove the fold mirror access panel.
Cold mirror
The cold mirror is located close to the integrator assembly.
Estimated replacement time: 20 m 30 minutes for calibration
1. Remove the
2. Remove the 2 screws securing the infrared emitter housing.
3. Remove and set aside the infrared emitter housing.
4. Remove one of the screws from each of the 3 clips securing the cold mirror.
i
When reinstalling the integrator assembly, adjust the integrator/fold mirror for
proper aperture alignment. See
Wear clean lint-free cotton gloves when handling the cold mirror and handle by the edges