Maintaining the projector
CP2306-RGBe, CP2308-RGBe, CP2310-RGBe User Manual
90
020-001835-02 Rev. 1 (05-2021)
Copyright
©
2021 Christie Digital Systems USA, Inc. All rights reserved.
6.
Slide the air filter out and inspect it.
If the filter appears dirty and you cannot see through it, replace it with a new paper filter, or clean
it if it is a washable filter.
If the filter appears clean, continue to step 7.
7.
Replace the air filter with the airflow indicator facing toward the projector.
8.
Install the cap plate and tighten the two captive screws.
9.
Install the service panel and then tighten the two screws.
10.
Install the top lid.
If the amount of dirt on the filter is minimal, use a vacuum or compressed air to remove it. If you use
compressed air, the air must move through the filter in the opposite direction of the air flow indicator on the
side of the filter.
Caution! If not avoided, the following could result in minor or moderate injury.
•
Install dry filters only. Wet or damp filters can cause an electrical short and damage the product.
1.
Hold the filter on an angle under warm running water so the water flows through the filter in the
opposite direction of the air flow indicator on the side of the filter.
2.
Rinse the filter thoroughly.
3.
Submerge the filter for a minimum of 30 minutes in a container of warm water and two tablespoons of
mild detergent or liquid dish soap.
4.
If the filter is extremely dirty, move the filter from side-to-side occasionally or remove the excess dirt
by brushing both sides of the filter with a soft brush.
5.
Rinse the filter thoroughly by holding it on an angle under cool running water.
The air flow arrow on the side of the filter should face down.
6.
If the filter still appears dirty, repeat steps 3 and 4.