7-8
CP2230 Service Manual
020-100562-06 Rev. 1 (05-2016)
Section 7: Specifications
7.5.2 7kW Lamp Power Supply
Nominal Voltage Range
Low line: 200-230 VAC
High line: 380-415 VAC
Operating Voltage Range
Low line: 180-253 VAC
High line: 342-456 VAC
Number of Phases
3
Line Frequency
50-60Hz nominal
Inrush current
120 A max.
Current per Phase
Low line: 35 A max.
High line: 23 A max.
Power Consumption
8.8 kW max. (at max. output for 6kW lamp plus head)
Current Rating of 3Phase AC Input
37A
Lamp Power Supply Output to Projection Head
Operating Voltage Range
18-46 VDC
Start-up Voltage (Open Current)
125-155 VDC
Operating Current Range
50-180 A
Ripple
1% max (at 25°C, rated input and rated output)
Connector Type
Field Wireable Lugs
Lamp Power Supply Power Receptacle Output
Operating Voltage Range
200-230 VAC
Operating Current Range - Projection Head
6 A
Operating Current Range - Heat Extractor
1 A
Current Rating of Input
Both run from 15 A breaker (internal)
7.5.3 UPS AC Input
Voltage Range
100 - 240 VAC
Line Frequency
50 Hz - 60 Hz nominal
Inrush Current
70 A maximum
Current Consumption
12 A maximum at 100 VAC
Power Consumption
1200 W maximum
Current Rating of AC Input
15 A maximum (Specified Wall Breaker)
Содержание CP2230
Страница 1: ...CP2230 S e r v i c e M a n u a l 020 100562 06...
Страница 2: ......
Страница 3: ...CP2230 S E R V I C E M A N U A L 020 100562 06...
Страница 18: ......
Страница 28: ......
Страница 52: ......
Страница 60: ......
Страница 114: ......
Страница 142: ......
Страница 144: ......
Страница 149: ......