5.5.6 Left Access Cover
Remove the left access cover, which is located next to
the lamp door to access any of the components in the
IOS and liquid cooling compartments.
(Estimated Replacement Time: 4 minutes)
1. Using a #2 Phillips
™
, loosen the three captive
screws at the top of the cover. (
)
2. Pull the cover up to clear the bottom tabs and
remove.
3. When re-installing the cover, align and insert the
bottom tabs first, then secure the cover with the
screws.
5.5.7 Lamp Door
Remove the lamp door to access components in the lamp compartment. The lamp door can be removed entirely
from the projector or it can remain tethered and opened up to 90°. Fixed to the inside of the door is a set of
commonly used hex keys required during lamp replacement.
(Estimated Replacement Time: 4 minutes)
1. Unlock and open the lamp door.
(
Figure 5-7
)
2. Unhook the securing tether on the
right-side of the door.
3. To release the door, slide the locking
pin (accessible through the cutout
located on the right side of the door)
towards the inside of the door.
Figure 5-7 Open Lamp Door