Section 5: Parts and Module Replacement
CP2230 Service Manual
5-19
020-100562-06 Rev. 1 (05-2016)
5.9.4 Snood (Integrator)
The snood is located before the integrator and is removed when the Dolby
®
filter wheel is used.
(Estimated Replacement Time: 2 minutes)
1. Remove the front top lid. Refer to
5.5.1 Front Top Lid, on page 5-6.
2. Remove the hex screw securing the snood. (
3. Remove the snood.
5.9.5 Integrator Assembly
Wear the gloves provided in the Service Kit whenever handling the integrator.
(Estimated Replacement Time: 12 m 15 minute calibration)
The integrator assembly is positioned on the IOS.
1. Remove the front top lid. Refer to
5-6.
2. Remove the two, 3mm hex screws securing the retaining clip
to the rear end of the integrator. (
Figure 5-27
)
NOTICE:
Perform this step with caution to avoid damaging
the temperature sensor mounted nearby.
3. Remove the snood. Refer to
5.9.4 Snood (Integrator), on page
.
4. Wearing the gloves provided with the Service Kit, carefully
remove the integrator assembly and set aside in a clean area
where it cannot be damaged.
5. When re-installing, repeat instructions in reverse. After
powering up the projector, adjust the integrator and fold mirror
as required for proper aperture alignment. For details, refer to
Figure 5-26 Screw
Securing Snood
Figure 5-27 Integrator Assembly
Содержание CP2230
Страница 1: ...CP2230 S e r v i c e M a n u a l 020 100562 06...
Страница 2: ......
Страница 3: ...CP2230 S E R V I C E M A N U A L 020 100562 06...
Страница 18: ......
Страница 28: ......
Страница 52: ......
Страница 60: ......
Страница 114: ......
Страница 142: ......
Страница 144: ......
Страница 149: ......