![Christ MAGNUM C5X00 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/christ/magnum-c5x00/magnum-c5x00_operation-manual_2603387064.webp)
Chapter 9
Software
64
6501288-EN / 04
9.2.3.1 Menu Information
Level
Value
Unit
min.
max.
Remark
Information
Information - menu
Revision:
0
0
0
Revision of the program
IP address
0. 0. 0.
0
Current IP address of the
control
stat
19
0
9999
Status number in the operation
terminal
In order to access the menu
Information
, proceed as follows on the operation panel, in
the menu
Operation terminal
.
•
Select the menu level
Information
with the key
[
]
or
[
]
.
CHRIST
MAGNUM
Information
<H> Home, <E> Enter, <
>, <
>
Acknowl
•
Confirm with the
[E]
key.
CHRIST
MAGNUM
Revision
<H> Home, <E> Enter, <
>, <
>
Acknowl
•
9.2.3.2 Menu Program selection
Level
Value
Unit
min.
max.
Remark
Program selection
Menu automatic program
selection
Select program again
0
Re-select the program auto-
matically after the wash
0:
no
1:
yes
Wash program:
0
0
32
Wash program number for the
automatic program selection
after the activation
Additional program 1:
0
0
1
Additional program 1 for the
automatic program selection
after the activation
0:
no
1:
yes
::
::
::
::
::
::
Additional program 8:
0
0
1
Additional program 8 for the
automatic program selection
after the activation
0:
no
1:
yes
Prog. selection blocked from
0
0
32
Conditioned program selec-
tion block, increasing counting
number
0:
no lock-out
1 -
32:
higher program
numbers are
locked including
the one input are
locked
Key assignment