Error
Cause
Switching
element
Input
Refer
er-
ence
value
F056: Water shortage brush wash
Water pressure for brush wash
insufficient
B52
K0.E42.9
0
F057: Water shortage brush/pre-
wash
Water pressure for brush wash /
pre-wash insufficient
B159
K1.E2.9
0
F058: Water shortage high-
pressure
Water pressure for high-
pressure insufficient
B161
K1.E2.11
0
F059: Water level storage tank
Water level in storage tank too
low
K280
K1.E2.12
0
F060: MS high-pressure oscillation
Motor safety switch for oscilla-
tion motor of the lateral nozzles
triggered
Q32,
Q42
K0.E43.4
1
F061: MS lifting motor horiz. nozzle
Motor safety switch for the
horizontal beam’s lifting device
triggered
Q40
K0.E45.4
1
F062: Rope switch horizontal noz-
zle
Rope operated switch of the
support for horizontal nozzles
triggered
B79A
B79B
K0.E45.DI12
1
F063: Rope safety horizontal nozzle Horizontal beam’s lifting cable
ruptured or loose
B72A
B72B
K0.E45.5
1
F064: Limit switch lift DD
At least two limit switches of the
lifting device for the horizontal
beam are simultaneously acti-
vated
B73,
B74,
B75
K0.E45.6,
K0.E45.7,
K0.E45.8
0
1
1
F065: Limit switch swivel DD
At least two limit switches of the
swivel drive for the horizontal
beam are simultaneously acti-
vated
B76,
B77,
B78
K0.E45.9,
K0.E45.10,
K0.E45.11
0
1
1
F066: Error horizontal brush
Free drive of the horizontal
brush impossible
internal
internal
F067: Error lateral brush
Free drive of the lateral brush 1
impossible
internal
internal
F068: DW control error status
Error in the horizontal brush’s
control
internal
internal
F069: SW control error status
Error in the control of the lateral
brushes 1
internal
internal
F070: FW control error status
Error in the control of the drive
unit
internal
internal
F071: Wash program time monitor-
ing
Program sequence too long
internal
internal
F072: Shortage fresh water pump
Water pressure for fresh water
supply too low
B160
K1.E2.10
0
F073: Door not closed
Door not closed at program start
K1.E3.5
K1.E3.6
1
1
F074: inclination SW2 left
Lateral brush 2 left goes too far
outwards
B67
K0.E44.7
1
F075: Inclination SW2 right
Lateral brush 2 right goes too
far outwards
B68
K0.E44.8
1
F076: Error limit switch SW2 left
At least two limit switches of the
outwards motion drive of the
lateral brush 2 left are activated
simultaneously
B61,
B62,
B63
K0.E44.1
K0.E44.2
K0.E44.3
0
1
1
F077: Error limit switch SW2 right
At least two limit switches of the
outwards motion drive of the
lateral brush 2 right are activat-
ed simultaneously
B64,
B65,
B66
K0.E44.4
K0.E44.5
K0.E44.6
0
1
1
F078: MS SW2 opening motor
Motor safety switch for outwards
motion drive of the lateral
brushes 2 released
Q28,
Q30
K0.E44.10
1
F079: MS brush motors SW2
Motor safety switch for the
lateral brushes 2 released
Q24,
Q26
K0.E44.9
1
M080: Water emptying active
Signal water emptying is active
B49
K0.AT49
M088: Danger of frost
Signal danger of frost is active
The temperature fell below the
minimum one required for the
wash.
B49
K0.AT49
M089: CPU dead battery
The battery of the CPU is dead.
Batterie
K1.CP1
F093: LON-Gateway interface
missing
LON-Gateway interface missing
internal
internal
F094: Interface module missing
Interface module missing
internal
internal
F095: Error in sequencer
Error in sequencer
internal
internal
F096: CRC error configuration
CRC error configuration
internal
internal
F097: EEPROM memory error
Memory error
internal
internal
F098: Error initial user
Error initial user
internal
internal
F099: Error initial system
Error initial system
internal
internal