Chapter 8
Operation
54
6501288-EN / 04
8.9
Shut down
8.9.1
General pointers
In case of danger of frost empty the water lines.
If the installation is shut down, the basic position of the components will not be monitored.
Exclude the access in the action area of the installation.
8.9.2
Dosing pumps
INFORMATION
Separate operation manual of the dosing equipment.
8.9.3
Shut down the installation
Take the installation out of operation:
1. If the function "lock the unit" is assigned to the key-operated switch of the operation
panel: lock the installation with the key-operated switch.
2. Close the gate valves in the water pipes.
3. Close the gate valves in the air supply.
4. If the option storm protection is available: lock the drive unit with the plug-in bolts of
the storm protection.
5. Switch off the main switch.