Chapter 14
Annexes
114
6501288-EN / 04
14.2
Table of errors
Error
Cause
Switching
element
Input
Refer
er-
ence
value
F002: Inclination SW left
Lateral brush 1 left goes too far
outwards
B37
K0.E42.1
1
F003: Storage tank osmosis
Storage tank osmosis empty or
overflow
B13, B14
-K1.E5.11
1
F004: Osmosis unit
Error in the osmosis unit
-K1.E5.12
0
F009: Inclination SW right
Lateral brush 1 right goes too
far outwards
B38
K0.E42.2
1
F010: Limit switch error FW
Two limit switches of the drive
unit are simultaneously activat-
ed
B25
B26
K0.E41.1
K0.E41.2
0
1
F012: Limit switch error DW
At least two limit switches of the
horizontal brush’s lifting drive
are simultaneously activated
B28
B29
B30
K0.E41.4
K0.E41.5
K0.E41.6
0
1
1
F013: Limit switch error SW right
At least two limit switches of the
outwards motion drive of the
lateral brush 1 right are simulta-
neously activated
B34
B35
B36
(B51)
K0.E41.10
K0.E41.11
K0.E41.12
(K0.E45.2)
0
1
1
1
F018: Safety strips
Emergency-stop device in the
portal interrupted
B01...B04
K0.E43.2
0
F019: Emergency-stop
Emergency-stop button activat-
ed or emergency-stop device
interrupted
S01...08
K0.E42.10
1
F020: Water preparation (FONTIS)
Error in the water preparation
unit
K1.E3.1
1
F022: Clock generator drive unit
Clock generator of the drive unit
defective
B27
K0.E41.10
1
F023: MS brush motors DW/SW
Motor safety switch for lateral
brush 1 or horizontal one re-
leased
Q14,
Q16,
Q18
K0.E42.5
1
F026: Limit switch error SW left
At least two limit switches of the
outwards motion drive of the
lateral brush 1 left are simulta-
neously activated
B31,
B32,
B33
(B50)
K0.E41.7
K0.E41.8
K0.E41.9
(K0.E45.1)
0
1
1
1
F030: Data transmission error
Data transmission error be-
tween machine control and
operation terminal
K1.SS1
internal
F040: Measured value DW missing
Power measurement value of
the horizontal brush missing
T61
internal
F041: Measured value DW too high Power measurement value of
the horizontal brush too high
T61
internal
F042: Idle run horiz. brush wrong
Power measurement value of
the horizontal brush wrong
T61
internal
F043: Meas.value SW left missing
Power measurement value of
the lateral brush 1 left missing
T61
internal
F044: Meas.value SWL too high
Power measurement value of
the lateral brush 1 left too high
T61
internal
F045: Idle run SWL wrong
Idle run of the lateral brush 1 left
wrong
T61
internal
F046: Meas.value SWR missing
Power measurement value of
the lateral brush 1 right missing
T61
internal
F047: Meas.value SWR too high
Power measurement value of
the lateral brush 1 right too high
T61
internal
F048: Idle run SWR wrong
Idle run of the lateral brush 1
right wrong
T61
internal
F049: PLC module error
PLC module not or wrongly
recognised
internal
internal
F050: DW rope safety
Lifting cable of the horizontal
brush ruptured or loose
B39A,
B39B
K0.E42.3
1
F051: MS frequency converter
motor
Error in the frequency converter
T63
K0.E42.4
1
F052: MS DW lifting motor
Motor safety switch for horizon-
tal brush’s lifting drive triggered
Q12
K0.42.6
1
F053: MS SW drawing aside motor
Motor safety switch for outwards
motion motor triggered
Q20,
Q22
K0.42.7
1
F054: MS dosing pumps
Motor safety switch for dosing
pumps triggered
F7
K0.E42.8
1
F055: MS additional equipment
Motor safety switch for addition-
al equipment triggered
F200,
F202,
F205,
F209
K1.E2.8
1