9.3 MOTOR SPINDLE MAINTENANCE
Make sure that the system is disconnected from the power supply before
carrying out any maintenance or adjustment work.
To access the motor spindle, open the electrical panel following the instructions in chap.9.
Then remove the 4 screws shown in Fig.20, that secure the protective casing, to access the motor spindle
mount.
- DO NOT LOOSEN THE SCREWS ON THE MOTOR SPINDLE
MOUNT
(Fig.21)
CAUTION
: Any accidental tampering with the mount screws will require a new alignment of the
INTERCHANGEABLE GUIDE-CUTTER assembly.
For any motor spindle fault, please contact our technical support department to better assess the problem
encountered and determine whether the part must be overhauled or replaced.
MOTOR SPINDLE MOUNT
Fig. 21
MOTOR SPINDLE
MOTOR SPINDLE PROTECTIVE
AND INSULATING CASING
FIXING SCREWS
Fig. 20
SCREW
MOTOR SPINDLE
SCREW
SCREW