3. If the ETH LED is flashing on/off on a .5s/.5s cycle, then the Ethernet
connection has not synchronised. This could be for a number of reasons:
•
Cable not connected properly.
•
Cable connected to wrong device or port on device (e.g. router).
•
Device to which cable connected not switched on.
4. If the ETH LED flashes off briefly every 1s, then this indicates that it is
synchronised but has not been given an IP address. The IRIS Dialler may
need to be set with a Fixed IP address (see Local Configuration sections).
Consult the local Network Manager.
4.4 Polling Configuration
1. To start up polling from the IRIS Dialler to the ARC, the Dialler must be loaded
with the IP address of the ARC and the account number of the dialler, both of
which can be loaded into the IRIS Dialler from the dialler.
2. Make sure the alarm dialler is set up with its account number. Set the IP
address of the ARC (i.e. twelve digits) into the ARC telephone number field in
the alarm dialler configuration.
3. Trigger the dialler to transmit an alarm. This dialler going off hook is indicated
by the DIAL indicator on the IRIS Dialler coming on. The IRIS Dialler will now
automatically pick up the account number and IP address from the information
transmitted by the dialler and start the polling process to the ARC.
4. Once the IRIS Dialler has successfully completed a poll to the ARC, the POLL
indicator comes on and remains on until the next poll. The installer can check
that polling is operating correctly by checking that the POLL indicator is on
and flickers off briefly (note – it may be so brief as to be unnoticeable) each
time a poll is made.
5. If the POLL indicator does not come on, this may be because the wrong
account number or ARC IP address have been entered. Set the IRIS Dialler
back to factory defaults, check the account number and IP address loaded
into the dialler and try again.
Alternatively, there could be some IP network connection problem making it
impossible for the IRIS Dialler to communicate with the ARC – consult the
local Network Manager.
6. The installer does not need to provide other parameters required for polling
e.g. polling interval and security key as these are loaded remotely by the ARC
when it receives the first polling call.
7. The configuration is stored by the IRIS Dialler in non-volatile memory and will
be retained even if power is removed.