8.2 Configuration
Configuration required for data calls can normally be done by the attached
equipment using Hayes commands. Depending on the network being used, the
commands are as follows:
8.2.1 General
Command Function
&F
Sets defaults for data port
S0=1
Sets auto-answer on (if required)
S0=0
Sets auto-answer off (if not required)
8.2.2 Calls over ISDN using V.120 Rate Adaption
Command Function
%A2=2
Selects V.120 calls over ISDN
The number dialled should be the ISDN telephone number of the destination.
8.2.3 Calls over Ethernet using TCP/IP
Command Function
%A2=12
Selects TCP/IP calls over Ethernet
%I6=abcde
Sets Dialler TCP port number to
abcde (must be five digits from)
%I7=fghij
Sets called TCP port number to fghij
(must be five digits)
The number dialled should be the IP address of the destination (12 digits). It is
also possible to include the destination TCP port number using the string :fghij
immediately after the dialled number, in which case the %I7 register does not
need to be set. An example of such a Hayes dial string is:
ATD192168001034:01233<CR>
This dials IP address 192.168.1.34 on port number 1233.
Version 1.5 16/10/06
24