8.2 Configuration 

 

Configuration required for data calls can normally be done by the attached 
equipment using Hayes commands. Depending on the network being used, the 
commands are as follows: 

8.2.1 General 

 

Command Function 

 

 

&F 

Sets defaults for data port 

S0=1 

Sets auto-answer on (if required) 

S0=0 

Sets auto-answer off (if not required) 

 

8.2.2  Calls over ISDN using V.120 Rate Adaption 

 

Command Function 

 

 

%A2=2 

Selects V.120 calls over ISDN 

 

The number dialled should be the ISDN telephone number of the destination. 

8.2.3  Calls over Ethernet using TCP/IP 

 

Command Function 

 

 

%A2=12 

Selects TCP/IP calls over Ethernet 

%I6=abcde 

Sets Dialler TCP port number to 
abcde (must be five digits from) 

%I7=fghij 

Sets called TCP port number to fghij 
(must be five digits) 

 

The number dialled should be the IP address of the destination (12 digits). It is 
also possible to include the destination TCP port number using the string :fghij 
immediately after the dialled number, in which case the %I7 register does not 
need to be set.  An example of such a Hayes dial string is: 
 
  ATD192168001034:01233<CR> 
 
This dials IP address 192.168.1.34 on port number 1233. 

Version 1.5    16/10/06 

24

Содержание IRIS 8 Series

Страница 1: ... uk com support chiron uk com Chiron Technology Ltd 2006 Version 1 5 16 10 06 The information contained is supplied without liability for any errors or omissions No part may be reproduced or used except as authorised by contract or other written permission The copyright and foregoing restriction on reproduction and use extend to all media in which the information may be embedded ...

Страница 2: ...IRIS 850 12 3 4 1 PCB Unit Front Panel Indicators and Connector 12 3 4 2 PCB Unit Rear Panel Connectors 12 3 4 3 PCB Unit Pin Inputs and Relay Outputs 12 4 INSTALLATION ALARM TRANSMISSION AND POLLING OVER IP 14 4 1 Preparation Prior to Installation 14 4 2 Physical Installation 14 4 3 Checking Network Connection 15 4 4 Polling Configuration 16 4 5 Alarm Transmission Configuration 17 5 INSTALLATION ...

Страница 3: ...S 23 8 1 Installation 23 8 2 Configuration 24 8 2 1 General 24 8 2 2 Calls over ISDN using V 120 Rate Adaption 24 8 2 3 Calls over Ethernet using TCP IP 24 8 2 4 Calls over GPRS using TCP IP 25 9 ADVANCED INSTALLATION PIN ALARMS 26 9 1 Installation 26 9 2 Default Alarm Messages 27 9 3 Configuration 27 10 ADVANCED INSTALLATION SMS MESSAGING 29 10 1 Installation 29 10 2 Configuration 29 11 ALARM PAN...

Страница 4: ...rm and Polling Security 36 15 5 Alarm System Upload Download 36 15 6 Alarm Interface 37 15 7 Ethernet Interface 37 15 8 ISDN Interface 37 15 9 PSTN Interface 37 15 10 GSM GPRS Interface 38 15 11 SMS Messaging 38 15 12 Data Interface 38 15 13 Pin Inputs 38 15 14 Relay Outputs 38 15 15 LED Status Indicators 40 15 16 Power Supply 40 15 17 Weights 40 16 CONFORMANCE AND SAFETY 41 16 1 Conformance 41 16...

Страница 5: ...16 3 Safety 42 Version 1 5 16 10 06 5 ...

Страница 6: ...lue to 40V peak Removed pin input sense resistors from inventory 1 3 22 5 06 Requirement to install in suitable enclosure is now mandatory rather than recommended 1 2 25 1 06 Added IRIS 840 1 1 29 12 05 Replace references to Velcro to self adhesive feet Included sense resistors in inventory Change references to IRIS Configuration Console to IRIS Configuration Software Added details for pin alarms ...

Страница 7: ...re reported to the ARC Advanced features such as data calls and SMS messaging are also offered The full set of features of each model in the range is included in the Specification section at the end of this User Guide The Installation sections of this Use Guide sets out a straightforward set of instructions for the installer from the most simple installation for alarm transmission over an IP netwo...

Страница 8: ...ey ISDN cable black PSTN cable grey Installation guide 18K sense resistor Antenna Optional Optional When using the Local Configuration Software a standard 9 way modem serial cable is required for connection of the IRIS Dialler to a lap top For the IRIS 840 and 850 the GSM SIM card can be obtained from the chosen GSM network operator Note that a SIM card offering both GSM and GPRS calls is required...

Страница 9: ...sed 3 1 IRIS 800 Note for the IRIS 800 the PCB version is narrower than the cased version 3 1 1 PCB Unit Front Panel Indicators DIAL ETH POLL PWR ETH 3 1 2 PCB Unit Rear Panel Connectors DIAL V24 3 1 3 Cased Unit Front Panel Indicators Alarm Adapter IRIS 800 DIAL SD ETH POLL RD TR 3 1 4 Cased Unit Rear Panel Indicators ETH V24 DIAL PWR Version 1 5 16 10 06 9 ...

Страница 10: ...OLL RD SD TR ISDN 3 2 2 PCB Unit Rear Panel Connectors PWR V24 ETH ISDN PSTN DIAL 3 2 3 Cased Unit Front Panel Indicators Alarm Adapter PSTN IRIS 820 DIAL SD ETH POLL RD TR ISDN 3 2 4 Cased Unit Rear Panel Connectors ISDN ETH V24 DIAL PWR PSTN Version 1 5 16 10 06 10 ...

Страница 11: ...3 3 IRIS 840 PCB Unit Indicators and Connectors V24 DIAL PWR DIAL GSM POLLLAN DTR SD RD PWR OUT C D OUT A B INPUTS 1 8 REF GND ANT ETH Version 1 5 16 10 06 11 ...

Страница 12: ...el Indicators and Connector ANT PSTN DIAL ETH POLL GSM RD SD TR ISDN 3 4 2 PCB Unit Rear Panel Connectors PWR PSTN DIAL V24 ETH ISDN 3 4 3 PCB Unit Pin Inputs and Relay Outputs OUT A B OUT C D REF GND INPUTS 1 8 PWR Version 1 5 16 10 06 12 ...

Страница 13: ...ata received on serial port TR Serial port connected ISDN ISDN network connection status The function of each connector is shown in the table below Name Function PWR Power in PSTN PSTN network connection DIAL Alarm dialler connection V24 Serial data port ETH Ethernet connection ISDN ISDN network connection SD GSM GPRS antenna connection OUT Relay outputs INPUTS Pin inputs for generating alarm or S...

Страница 14: ... is the same as required for any standard dialler installation 4 The IRIS Dialler should be set to factory defaults If it is believed that the Dialler has been used before on another site and retains that configuration it should be set to defaults The way to do this is describer in the Local Configuration sections of the User Guide 5 The IRIS Dialler has an Ethernet interface for IP network connec...

Страница 15: ...ity on this Dialler 6 Use the Ethernet cable provided Cream to connect the ETH interface on the IRIS Dialler to the local router hub switch etc that gives access to the IP network The cable provided is terminated at both ends with an RJ45 plug that is the standard interface used for Ethernet connections on most equipment Make sure this cable run is protected from tampering Note it is essential tha...

Страница 16: ...RIS Dialler coming on The IRIS Dialler will now automatically pick up the account number and IP address from the information transmitted by the dialler and start the polling process to the ARC 4 Once the IRIS Dialler has successfully completed a poll to the ARC the POLL indicator comes on and remains on until the next poll The installer can check that polling is operating correctly by checking tha...

Страница 17: ...e DIAL indicator on the IRIS Dialler will come on 3 If a backup or second path is required the twelve digit IP address of the second receiver should be programmed into the second ARC telephone number field of the dialler 4 Having set up the alarm transmission as required it is strongly recommended that all routes are tested by generating alarm signals During alarm call testing a standard PSTN line...

Страница 18: ...on is not important 2 If alarm communication over ISDN is required connect the ISDN network interface on the IRIS Dialler to the ISDN service using the Black cable provided This cable is terminated at both ends with an RJ45 plug and this is the standard interface for ISDN services 3 Make sure all cable runs are routed so as the protected against tampering 5 3 Checking Network Connection 1 If the P...

Страница 19: ...ropriate cable 3 Most alarm diallers allow two ARC numbers to be programmed which can be used in primary backup mode or for dual path signalling Various combinations of routing can therefore be set up depending on the numbers entered Primary and secondary routes over IP Primary route over IP and secondary route over dial up PSTN or ISDN Primary and secondary routes over dial up PSTN or ISDN Primar...

Страница 20: ...a so as to be protected against tampering 2 Insert the SIM card into the holder in the IRIS Dialler If the cased version of the Dialler is being used the casing can be unscrewed with the four screws under the self adhesive feet to give access to the SIM card holder Note the IRIS Dialler must always be disconnected from power when inserting or removing the SIM card otherwise damage to the SIM card ...

Страница 21: ...he section above the IRIS Dialler will automatically poll over GPRS to the same ARC IP address if it cannot complete a poll over IP 2 The POLL indicator indicates poll success as with polling over IP 6 5 Alarm Transmission 1 If the IRIS Dialler is unable to make an alarm call over IP it will automatically retry to the same ARC IP address over GPRS Version 1 5 16 10 06 21 ...

Страница 22: ...be disconnected from power when inserting or removing the SIM card otherwise damage to the SIM card can result 7 3 Alarm Transmission 1 Transmission over GSM is selected by configuring the alarm dialler with one of two leading digits before the telephone number as with PSTN and ISDN 9 the IRIS Dialler will route the call over GSM only if PSTN and ISDN are not available This facility is used for st...

Страница 23: ...ce unit to the Dialler serial data port labelled V24 using a standard modem cable Note the Dialler automatically detects whether the Local Configuration Software or another device is connected to the serial port If the serial port has been used for configuration there are no changes that need to be made 3 Configuration of the Dialler for data calls is via Hayes format commands This can normally be...

Страница 24: ... telephone number of the destination 8 2 3 Calls over Ethernet using TCP IP Command Function A2 12 Selects TCP IP calls over Ethernet I6 abcde Sets Dialler TCP port number to abcde must be five digits from I7 fghij Sets called TCP port number to fghij must be five digits The number dialled should be the IP address of the destination 12 digits It is also possible to include the destination TCP port...

Страница 25: ...tion A2 19 Selects TCP IP calls over GPRS I6 abcde Sets Dialler TCP port number to abcde must be five digits from I7 fghij Sets called TCP port number to fghij must be five digits Dialling is as described in the section above Version 1 5 16 10 06 25 ...

Страница 26: ...onfiguration of these functions is via the Local Configuration Software Note that if the Polling information for the IRIS Dialler account and IP address of ARC is not set up already from a connected alarm dialler see above then this information must be loaded from the Local Configuration Software This section describes the pin alarm function The section below covers the SMS function 9 1 Installati...

Страница 27: ... on this Dialler 9 2 Default Alarm Messages The default SIA messages for each pin are shown below Pin Set message Restore message Meaning 1 NBA NBR Burglary alarm restore 2 NFA NFR Fire alarm restore 3 NQA NQR Emergency alarm restore 4 NCL NOP Open close 5 NPA NPR Panic alarm restore 6 NUA NUR Other untyped alarm restore 7 NAT NAR Power failure alarm restore 8 NTA NTR Tamper alarm restore By defau...

Страница 28: ...lling account code SIA Messages sent are determined by the contents of the Message Sent When Activated field This field contains the Set message followed by the Restore message separated with a _ character Note that each part of the message contains both the SIA Function code and the SIA Message e g NBA1002_NBR1002 Only a Set alarm is sent if no Restore message is included Entry starting with vari...

Страница 29: ...he screw blocks on the IRIS Dialler Note that outputs A and B are normally closed and outputs C and D are normally open 3 If a confirmation SMS message is required when an output is activated it is suggested that the output is also connected to a spare input This input can be configured to send a message back to the command originator 10 2Configuration Configuration of the SMS functions is done fr...

Страница 30: ...4 It is recommended that inputs and outputs selected are tested by the installer while on site Version 1 5 16 10 06 30 ...

Страница 31: ...8 For routing of calls over ISDN or PSTN the telephone number programmed in the dialler must be telephone number of the receiver prefixed with the digit 9 9 The routes over PSTN or ISDN depending on which network is connected Calls made into the Dialler either over IP ISDN or PSTN are routed to the DIAL port that will send the ring signal to the dialler in the normal way For calls over ISDN or PST...

Страница 32: ...ton and select Run Click the Browse button and open the CD ROM drive normally D Double click on Setup and then click on OK to start installation Follow the instructions on the screen 12 2Connecting to the Dialler Connect the selected COM port on the PC or Laptop to the serial data port on the Dialler using a standard modem cable 12 3Running the Configuration Software The configuration software can...

Страница 33: ...lt configuration use 9 1234567890 13 2 IP Address By default the Dialler will automatically negotiate its IP address with the IP network If a fixed address is required this address will be allocated by the IT manger the following commands are used to set the IP address and related IP parameters Own IP address 65 0 nnnnnnnnnnnn 12 digits Sub net mask 65 1 nnnnnnnnnnnn 12 digits Default Gateway addr...

Страница 34: ...er it should be defaulted and the procedure repeated There is a cabling or IP network problem check the cabling and connections There is a polling key mismatch between the ARC and the Dialler Set Dialler back to default and repeat setup for polling Also reset ARC entry for this device Dialler does not successfully signal an alarm The dialler is using the wrong number to call Check the receiver num...

Страница 35: ...nsmission over GSM Y Y Alarm panel upload download over IP Y Y Y Y Alarm panel upload download over PSTN or ISDN Y Y Substitution protection Y Y Y Y Play back protection Y Y Y Y Alarm encryption Y Y Y Y Tamper proof Y Y Y Y Battery backup compatible Y Y Y Y SMS messaging Y Y Pin inputs alarms or SMS 8 8 Relay outputs via SMS 4 4 Serial data transmission over IP Y Y Y Y Serial data transmission ove...

Страница 36: ...larm messages acknowledgement by receiver to ensure reliable transmission Fast Format Scancom Contact ID and SIA to Level 3 supported Primary and backup routes configurable Uses TCP connection outbound from IRIS Dialler to port number 53165 at ARC 15 4 Alarm and Polling Security Protection against substitution on IP networks by authentication using CHAP MD5 algorithm Alarm messages over IP encrypt...

Страница 37: ...0 100BaseT with auto negotiation UTP with standard RJ45 socket for CAT 5 cabling Auto sensing of Ethernet 802 2 DIX and SNAP formats ARP Address Resolution Protocol support Dynamic IP addressing DHCP 15 8 ISDN Interface Basic Rate 2B D Q 921 Q 931 S bus compatible Conforms to European ETSI standard TBR 3 RJ45 socket with cable provided Point Point and Point Multipoint operation Multiple Subscriber...

Страница 38: ... incoming SMS messages Optional validation of caller number for incoming SMS messages 15 12 Data Interface Asynchronous 9 pin RS232 interface Autobauding to 115 2 Kbps Data format 8 bit 1 stop bit with parity auto detect none even odd Hayes AT compatible RTS CTS flow control 15 13 Pin Inputs Maximum input voltage range 0V to 24V Input low threshold 2V Input high threshold 3V Input pull up impedanc...

Страница 39: ...Version 1 5 16 10 06 39 ...

Страница 40: ...t dialler off hook 195mA supply at 12V IRIS 840 typical current dialler on hook 185mA supply at 12V IRIS 840 typical current dialler off hook 215mA supply at 12V IRIS 850 typical current dialler on hook 185mA supply at 12V IRIS 850 typical current dialler off hook 215mA supply at 12V Note these figures are based upon the Ethernet link being connected Also on the IRIS 840 and 850 there will also be...

Страница 41: ...ble to the IRIS Diallers should be kept less than 3m length 16 2Conformance to EN50131 and EN50136 The IRIS Diallers are compatible with the requirements of European standards prEN50131 1 Alarm systems Intrusion and hold up systems Part 1 System Requirements Dated Feb 2004 and EN50136 1 1 Alarm systems Alarm transmission systems and equipment January 1998 with Amendment 1 August 2001 as follows Th...

Страница 42: ...nst these standards by Telefication B V 16 3Safety Care should be taken that when interconnecting telecommunications equipment that only like interfaces are interconnected to avoid safety hazards The interfaces on the IRIS Dialler have the following safety classifications ISDN Interface TNV operating at SELV and suitable for connection to Basic rate ISDN interfaces provided by a Public Telecommuni...

Страница 43: ...ditions carries telecommunications signals 70 7V peak or 120V dc maximum SELV Safety Extra Low Voltage is defined as a secondary circuit which is so designed and protected that under normal and single fault conditions the voltage between any two accessible parts does not exceed a safe value 42 4V peak or 60V dc maximum ...

Отзывы: