User Manual

T40 Portable Ground Control Station

(July, 2021)

V 1.0.3 video&data&RC link V21 V30 V40

Содержание T40

Страница 1: ...www chinowing com 1 User Manual T40 Portable Ground Control Station July 2021 V 1 0 3 video data RC link V21 V30 V40 ...

Страница 2: ...gs 22 7 T40 GCS Operation 23 7 1 Remote Control Power on and Power Off 23 7 2 Indicator Instruction of GCS and Receiver 24 8 T40 GCS Parameters Setting Software Operation 28 8 1 Parameters Setting Software Instruction 28 8 2 Channel Monitoring and Calibration 28 8 3 Channel Configuration 29 8 4 Key Setting 33 8 5 Failsafe Setting 35 8 6 External SBUS Input 37 8 7 Other Settings 37 8 8 T40 Alarm In...

Страница 3: ...ruction Sheet 57 12 V40 Video Link Module Operation and Use 60 12 1 V40 Connection Instruction 60 12 2 Serial Port Configuration Instruction 61 12 3 Serial Port Configuration Modification Instructions 63 12 4 V40 HDMI Operation Instruction 67 12 5 Airborne LAN Port Operation 69 13 Video Link Parameters 71 13 1 V40 Video Link Parameters 71 13 2 V21 Video Link Parameters 72 13 3 V30 Video Link Param...

Страница 4: ...40 Frequency 800MHz 1 4GHz and 2 4GHz for choice Default 1 4GHz Frequency Range 800M 806 826MHz 1 4G 1427 9 1447 9MHz 2 4G 2401 5 2481 5MHz 3 The ground unit is with built in 16 8v battery 4S lithium battery the airborne unit needs external power input DC7 4 24v 2S 6S lithium battery Please power the system in strict accordance with specifications 4 With improper operation the aircraft may cause a...

Страница 5: ... our company 2 Be sure to install the antennas before power on to avoid damage to the circuit 3 Try to make the receiver antenna without obstruction and the end part of the antenna is vertically downward without bending so as to avoid shortening the communication distance or even failing to communicate due to obstruction 4 Do not disassemble or refit without permission If you encounter any problem...

Страница 6: ...tered the state of out of control protection Stop using it when the battery is too low Don t rely on the device s low power alarm which is only a precaution and tells you when to charge It takes about 2 5hs to be fully charged 3 Product Introduction T40 is all in one hand held GCS that integrates remote control data transmission module video transmission module and industrial computer High integra...

Страница 7: ...r V21 receiver Fibre glass epoxy antenna TNC sucker 2 TNC fibre glass epoxy antenna 2 Accessories Cables XT40 power cable 1 SBUS signal wire GH 3pin 2 TTL signal wire GH 4pin 1 Aviation plug 6pin 1 Charger 1 DC16 8V charging for RC LAN to 4Pin wire 1 used for module parameters setting ...

Страница 8: ...l 1 V30 Receiver TNC ZYJB antenna 2 For T40 remote control SMA ZYJB antenna 2 For V30 receiver Fibre glass epoxy antenna TNC sucker 2 TNC fibre glass epoxy antenna 2 Accessories Cables XT40 power cable 1 SBUS signal wire GH 3pin 2 Charger 1 DC16 8V 6V charging for RC ...

Страница 9: ...com 9 TTL signal wire GH 4pin 1 HDMI wire HDMI A to micro Aviation Plug 6pin 4 3 V40 Version Main module T40 Remote Control 1 V40 Receiver TNC ZYJB antenna 2 For T40 remote control SMA ZYJB antenna 2 For V40 receiver ...

Страница 10: ...nna TNC sucker 2 TNC fibre glass epoxy antenna 2 Accessories Cables XT40 power cable 1 SBUS signal wire GH 3pin 2 TTL signal wire GH 3pin 1 GH 4pin 5 Charger 1 DC16 8v 6A charging for RC LAN to 4Pin wire 1 HDMI to HDMI micro 1 Aviation plug 6pin ...

Страница 11: ...wer off the GCS 4 Upper screen brightness used to adjust the brightness and Menu up 5 Upper screen brightness used to adjust the brightness and Menu down 6 External HDMI Switch for external HDMI and computer split screen switching 7 Menu key of upper screen function used to enter menu settings of the upper screen 8 Touch panel Used to control the mouse cursor 9 Main joysticks corresponding to T1 T...

Страница 12: ...lug corresponding to RS232 Level COM4 2 channels of SBUS 18 4 Pin Aviation Plug corresponding to LAN port of the computer 19 SIM card slot for installing SIM card 20 3 RS232 serial port corresponding to COM1 COM2 COM3 21 External SBUS input corresponding to SBUS2 signal output 22 Audio interface and LAN port for audio output and Ethernet connection 23 USB VGA HDMI interfaces used for SUB communica...

Страница 13: ...port S BUS1port SBUS input ground unit SBUS output airborne unit S BUS2 port SBUS input ground unit SBUS output airborne unit Power supply port 7 4 12V TTL signal indicator light will flicker when there is data input SBUS1 indicator Ground unit SBUS1 indicator will flicker when there is data input of SBUS1 Airborne unit SBUS1 indicator will flicker when there is data output of SBUS1 SBUS2 indicato...

Страница 14: ...V21 Receiver Installation and Connection 1 Connecting antennas to SMA port of Rx 2 Fix the receiver to the appropriate position of the aircraft by using double sided tape 3 As shown in the above photo connecting TTL port and S Bus port of the V21 receiver to your device by lead wire of servo TTL port SBUS port RX TX S S Receiver GND GND Flight control Receiver Flight control TX RX or other device ...

Страница 15: ...ng description The receiver power is 1W by default please keep the receiver antenna away from other electronic devices GPS compass etc to avoid interference with it and affect the flight Make sure to install the antennas before power on otherwise it may burn out the radio module When using the antenna try to make the antenna downward and no obstacle blocking to avoid the communication distance is ...

Страница 16: ...ished Signal strength indicator S3 ON signal is weak S3 and S2 ON signal is moderate S3 S2 and S1 ON signal is strongest Side View Data transmission port TTL level in transparent transmission with the COM6 in the computer SBUS 1 port used for connecting flight controller or payload SBUS 2 port used for connecting flight controller or payload Power supply port 7 4 12V HDMI video input interface con...

Страница 17: ...6 channels 5 3 2 V30 Receiver Installation and Connection 1 Connecting antennas to SMA port of Rx 2 Fix the receiver to the appropriate position of the aircraft by using double sided tape 3 As shown in the above photo connecting COM port and S Bus port of the V30 receiver to your device by lead wire of servo TTL port SBUS port RX TX S S Receiver GND GND Flight control Receiver Flight control TX RX...

Страница 18: ...ans the successful connection between Receiver and Remote Control 6 If you are using Receiver with dual SBUS output SBUS1 and SBUS2 will output control signal of CH1 CH16 channels from Remote Control And SBUS1 and SBUS2 can be mapped separately By default the S BUS1 and S BUS2 interfaces output the CH1 to CH16 of the remote control to 1 16 channels 5 4 V40 Receiver 5 4 1 V40 Receiver Indicator Por...

Страница 19: ...ilure SET button For out of control protection Settings POWER indicator Data link establishing indicator Indicator to indicate the data link connection status between the airborne unit and the ground unit Signal strength indicator Indicator S1 S2 S3 are used for indicating signal strength HDMI interface HDMI video input CVBS video input interface CVBS video input LAN port Used for transmit the vid...

Страница 20: ...5V RX TX S S Air GND GND Flight control Air Flight control TX RX or other device or other device 2 RS232 port and RS485 port connection sequence RS232 port RS485 port 5V 5V 5V 5V GND GND GND GND Air TX RX Flight control Air A A Flight control RX TX or other device B B or other device 3 With a stable 7 4 24V DC power supply POWER indicator ON indicates that the transmitter is normally powered on wh...

Страница 21: ...en for the computer extension screen when the upper screen can only use touch Touch is only available on the upper screen when the secondary screen is an extension of the computer When there is external HDMI video input press to switch external video source display buttons they are used to adjust the brightness of the upper screen button upper screen Menu it used to adjust the screen configuration...

Страница 22: ... is needed at this time 3 As shown below just follow the computer prompts 4 In the Display Options select 1 Mobile PC Display and 2 LONTIUM respectively for calibration and then the user can do the calibration normally After calibration it can be used normally 6 2 Split Screen Settings Screen display factory settings is for the upper and lower split screen If the user is not used to it pls right c...

Страница 23: ...e Control Power on and Power Off Please pay attention to the power button power indicators and 4 power indicators 25 50 75 100 5 data link indicators RS1 RS2 RS3 TX RX during the switching process of T40 1 Long press the power button the power indicator light is on and then according to the speed of the release action of the button to decide whether the computer is turned on or not ...

Страница 24: ...r is in the boot state the system will first shut down the computer before shutting down the remote control When you do not use your computer for a long time please turn it off in time to avoid the power consumption If it is found that the long press the power button cannot start up the system it is likely that the battery is with low capacity Please charge it by standard adapter 7 2 Indicator Ins...

Страница 25: ...s on in normal working condition Off The radio is off in the condition of power off Power indicator light 25 flicker other 3 Off Less than 25 power capacity 25 ON other 3 Off Power capacity between 25 50 25 50 ON other 2 Off Power capacity between 50 75 25 50 75 ON 100 OFF Power capacity between 75 100 25 50 75 100 ON Full capacity 100 4 lights flicker and the buzzer with continuous short sound Hi...

Страница 26: ...nal strength indicator RS1 RS2 RS3 RS1 RS2 RS3 ON Strong signal RS1 RS2 ON RS3 OFF Moderate signal RS1 ON RS2 RS3 OFF Weak signal RS1 RS2 RS3 OFF or Show the running horse lights No connection S1 S2 S3 Sharp flash Outputting Failsafe protection data 7 2 3 Indicator Instruction of V30 Receiver Indicator Status Define CPU Flashing No video signal input Continuously ON There is video signal input LIN...

Страница 27: ...ere is signal transmission for both SBUS COM Light OFF Serial port module to be started or failed Continuously ON Serial port module is working normally HDMI Light OFF HDMI port without video source input Continuously ON HDMI port with video source input WORK Light OFF System self check or system failure Continuously ON The system self check is normal and able to work RXD Light Flashing The receiv...

Страница 28: ...ting Software Operation 8 1 Parameters Setting Software Instruction T40 Parameters Setting Software CHINOWING Version no V1 0 Power on GCS open CHINOWING software then enter the main interface as shown above 8 2 Channel Monitoring and Calibration ...

Страница 29: ...ameters setting software display matches the action to verify that the calibration was successful The channel display of the remote control is divided into three parts The left part shows the output value of SBUS 1 the middle part shows the corresponding status of each channel and the right part shows the output value of SBUS 2 SBUS1 and SBUS2 can be configured separately 8 3 Channel Configuration...

Страница 30: ...afe protection function of the current channel works set the value of the corresponding dialog box the current value is the pwm value of the out of control after setting please verify by flight control ground station or servo 4 There are three operation modes American mode Japanese mode and Chinese mode 1 American mode 2 Japanese mode ...

Страница 31: ...ick once to write a new configuration data Load configuration call different storage profiles Save configuration save the current configuration as a configuration file for easy finding Restore default restore all parameters of the current page to default values After each configuration change click write data button and the changed configuration can take effect When the remote control mode is conf...

Страница 32: ...hinowing com 32 Japanese mode American mode Chinese mode The default control mode of T40 is the American mode This manual uses the American hand as an example to illustrate how the remote control is operated ...

Страница 33: ...d one decremental Single step increment sets the value incrementing that value or decrementing the value each time it is pressed After setting set the key combination as ckey1 ckey5 and then it can be output Red light always on when pressed red light not OFF when released red light off when pressing other Combination Buttons Super Combination Key Settings Click Channel Configuration Keys Setting S...

Страница 34: ...nel setting interface and then it can be output When the button is pressed the corresponding output fixed value can be output press this button red led light will be ON release the light will be OFF Set key attributes click Channel Configuration Key Settings Key Attribute Settings 12 buttons each button can be set to mono state bi state tri state SBUS channel is set to the corresponding key when p...

Страница 35: ...FF Tri state No press the channel output 0 green light OFF press the channel output 100 green light and fast flashing press again the channel output 0 green light OFF press again channel output 100 slow flashing 8 5 Failsafe Setting 1 Failsafe setting click on the white box in front of the channel that needs to open the failsafe function When there is a in the white box it means the current channe...

Страница 36: ... written If not the setting is failed and needs to be set again After successful setting the output value will be the pwm value After setting please verify with the flight control ground station or servo The failsafe data is only output by receiver when there is no signal transmission Each time the configuration is successfully set up it can be verified by the flight control ground station or serv...

Страница 37: ...shows the upper computer setting to output external SBUS data 8 7 Other Settings 1 Alarm time is the alarm time for long time no operation of the joystick Default is 10 minutes adjustable from 0 to 120 minutes 2 Alarm voltage is the low battery alarm voltage of the GCS Default 13 2V adjustable 3 Hardware Voltage is the real time voltage value of the GCS battery 4 Transparent transmission baud rate...

Страница 38: ... red When the battery voltage rises to alarm recovery voltage the alarm will stop In the alarm process before the battery voltage drops to low voltage shutdown voltage the buzzer will be faster than the normal alarm frequency 5 10 minutes without charging ground station will automatically shut down to protect and stop working T40 alarm recovery voltage is 0 3V higher than the set alarm voltage T40...

Страница 39: ... the endurance time 9 T40 GCS External Ports Instruction 9 1 COM Port Connection Instruction T40 computer comes with 6 COM ports among which COM5 and COM6 are for internal use only COM5 is a special port for Parameters Setting Software COM6 is a serial data transmission port for remote control COM4 is an aviation plug other COM ports are converted to different signals by hardware and lead to data ...

Страница 40: ...uction T40 without communication version is with 1 channel of LAN signal 2 channels of SBUS signal and 1 channel of RS232 signal to communicate with external devices T40 with communication version 4 Pin LAN port no output among 6 Pin port 2 channels of SBUS signal and 1 channel of RS232 signal to communicate with external devices Aviation Plug 4pin is LAN port 6pin is 2 SBUS signal and RS232 signa...

Страница 41: ...l connection of two modules S1 S2 and S3 lights are always on and the signal indicator is constant this process takes about 20 30 seconds the device can be used normally All parameters of the remote control and receiver module have been configured well at the factory and can be used directly If you want to modify the serial port baud rate and the IP address of the LAN port please refer to the corr...

Страница 42: ...d to the airborne unit The ground unit does not need to change the baud rate just open the ground station and select 115200 to connect Serial Port Baud Rate Change Press and hold the SET key approx 2 seconds after power on the airborne unit Release when RX and TX are illuminated it indicates entering the serial port baud rate change mode After entering the mode press the SET key briefly 1 second t...

Страница 43: ... ground station The baud rate will only be effective after the modification is completed and the power is reapplied 10 3 V21 LAN Port Use 1 Default IP address Airborne unit 192 168 168 2 Ground unit 192 168 168 1 2 Connect the V21 and LAN camera by 4pin to LAN cable And then power on by 7 12V power supply LAN port of T40 internal module has been connected to the LAN port 3 To connect the LAN camer...

Страница 44: ... Open the network pulling player Here take VLC for example the first step to open the VLC software the second step in the media to open the network streaming as follows 7 Enter the LAN camera address rtsp 192 168 168 20 554 user admin password channel 1 stream 0 sdp 8 The other characters are filled in according to the camera s setup parameters which are usually equipped with software for viewing ...

Страница 45: ...k segment as the IP camera Please visit our website www chinowing com for video tutorials 10 4 V21 Video Data Link Quick Reset and Configuration If the video data link becomes unresponsive during use it is needed to restore the module to factory settings and then configure the parameters Configure the airborne unit as the master mode and configure the the ground unit as the slave mode 10 4 1 V21 V...

Страница 46: ...network segment as the IP of the airborne unit for example 192 168 168 15 Open a browser and enter IP 192 168 168 1 in the address bar When the login screen of the device pops up click Administrator Login user name admin123 password admin123 If the login does not respond or if you are prompted with This browser does not support ActiveObject please download another browser e g Sogou or Microsoft Ed...

Страница 47: ... com 47 After successful login the module configuration interface appears The Key Setting Management allows you to set the secret key which must be the same for both the airborne unit and ground unit to communicate ...

Страница 48: ...h please make sure the frequency band and bandwidth of the airborne unit and ground unit should be the same the antenna model used is consistent with the frequency band The modification of power can be made in Building Chain Management For example changing 10dbm to 10dbm in the power range of 40db 25dbm IP Address Change Management can modify IP addresses It is not recommended to change the IP add...

Страница 49: ...o of downlink and uplink is 1 4 The Debug Interface should be modified at the developer s guidance If the user needs a fixed frequency point output use the AT command AT DRPS The first parameter is the frequency point range please set it according to the frequency point range of different frequency bands The second parameter is the bandwidth 1 is 3M 2 is 5M 3 is 10M 5 is 20M The third parameter is...

Страница 50: ...on the airborne unit connect V30 HDMI port to the camera and the CPU indicator is continuously ON when there is video input 2 The LAN port of the internal module of the T40 remote control has been connected to the network port After the successful connection check that the computer and set its network settings TCP IPV4 properties to 192 168 168 xxx xxx is the address value in the middle of 0 to 25...

Страница 51: ...irst step is to open the VLC software 2 the second step is to open Network Streaming in Media as shown below 3 Step 3 Enter the pull stream IP address Note the default IP address of the V30 receiver in the factory setting is 192 168 168 13 enter the following address ...

Страница 52: ...linking note that the baud rate of the flight control and the V30 or ground station need to be the same otherwise the link cannot be established 11 2 Display the Video in Mission Planner First verify that the video stream is available in video software such as VLC and open MISSIONPLANER 1 Press the right mouse button or long press in the HUD window 2 Click VIDEO 3 Click GetGstreamer source 4 Enter...

Страница 53: ...chinowing com 53 5 For the first time usage download the relevant software package and wait for the download to complete Restart software 6 After finishing steps 1 4 the camera video source can be obtained ...

Страница 54: ... com 54 7 The video interface and mission planning interface can be switched by right click 11 3 Display Image in QGC Software First verify the video stream can be obtained in video software such as VLC and open QGC ...

Страница 55: ...coding it is needed to input in the browser IP 192 168 168 13 to log in V30 Transmitter 2 Change the video encoding mode to H 264 3 Open QGC software Click general and find video VIDEO source chooses RTSP VIDEO STREAM in RTSP URL input RTSP 192 168 168 13 stream0 ...

Страница 56: ...he device is powered on the CPU light flashes indicating the successful device initialization 3 Enter serial port configuration mode Note that the COM6 port is used for the T40 and the port number of the tool is used for the V30 receiver Use the serial port tool on the computer set the baud rate to 115200bps the data bit to 8 the stop bit to 1 no parity bit and no flow control After opening the se...

Страница 57: ...ow configure the serial port baud rate to 115200 enter the command AT SBR 115200 The device returns OK to indicate successful modification If showing ERROR it indicates the command input is wrong or the parameter is invalid 11 5 Supporting Instruction Sheet Type Command Parameters Value Parameter instruction Setting RF transmitting power AT SPWR 1 Low power 15DBm 2 Moderate power 20DBm 3 High powe...

Страница 58: ... Bandwidth AT SBW 1 3M 2 5M 3 10M 5 20M Set the master slave mode AT SMOD 1 Central node main mode 2 Slave node slave mode Set the fixed frequency mode AT SFIX type Freq 0 Type 0 cancel the fixed frequency mode 1 Type 1 set the fixed frequency mode Freq 8060 8259 14279 14478 24015 24814 17850 18050 Query the setting value of the current configuration of the device enter the following command Type ...

Страница 59: ...0MHz 800MHz 1 4GHz 1 4GHz 2 4GHz 2 4GHz Query baud rate of serial port AT GBR xxxxxx Current baud rate value Query KEY AT GKEY XXXXX Current KEY Query fixed frequency status AT GFIX xxxxx Return fixed frequency status Query bandwidth AT GBW xxxxx Return the current bandwidth value Query main slave mode AT GMOD DDTC 1 1 Main mode DDTC 2 2 Slave mode Query software version no AT GVER Return the MCU ...

Страница 60: ... directly If you would like to change the serial port baud rate and the LAN Port IP address of data link please refer to the corresponding sections Video Link Serial Port IP address Name IP Address Video link Ground IP 192 168 168 1 Video link Airborne IP 192 168 168 2 Serial Port Airborne IP 192 168 168 19 All of the above IP addresses can be accessed in the PC s browser and able to do the parame...

Страница 61: ...e V40 e g 192 168 168 35 V40 video link web login user name admin123 password admin123 Serial port web login user name admin password admin 12 2 Serial Port Configuration Instruction Baud rate of V40 all serial ports 115200 Default IP address 192 168 168 19 Operating mode TCP Server Serial port operating mode Item Operating mode Local port External port Airborne unit TCP Server 10 TTL 20 RS232 30 ...

Страница 62: ...otocol for communication open the Mission Planner select TCP communication method enter the airborne unit serial port IP address 192 168 168 19 The port should be selected as the external interface corresponding to the airborne uni Establish the connection baud rate does not need to be selected If you are using RS232 port number is 20 RS485 corresponding port number is 30 12 2 2 Virtual Serial Por...

Страница 63: ...work If you are using a COM port for communication the user can use the virtual port tool to virtualize the network connection as a port Click on Add protocol TCP client select the virtual serial port COM4 network protocol TCP Client target IP 192 168 168 19 this IP is the IP of the module target ports 10 20 30 corresponding to the TTL RS232 RS485 of the airborne unit create the serial port com4 T...

Страница 64: ...IP address e g 192 168 168 35 Open the browser and enter 192 168 168 19 to connect to the ground unit serial port module to enter the web configuration interface User name admin Password admin After entering in the upper right corner Chinese and English versions can be switched 3 channels of serial port settings corresponding to the V40 external interface port 1 TTL port 2 RS232 port 3 RS485 if th...

Страница 65: ...the corresponding baud rate to save the settings the baud rate supports 600 230400bps Serial ports supports TCP Server TCP Client UDP Httpd Client WEB to Serial Websocket etc Default working mode airborne unit TCP Server local remote 3 ports are 10 20 30 ...

Страница 66: ...FI just fill in the port number of the remote airborne unit port number in the ground end If the connection is made via the device s external interface it is necessary that the serial signals on both sides of the V40 are identical otherwise no communication can take place Advanced settings where the module name user name and password can be changed and the data reset time defaults 60 seconds do no...

Страница 67: ... to the section of V21 module configuration for configuration of V40 module 12 4 V40 HDMI Operation Instruction Connect the HDMI video source from the camera to the HDMI port V40 Air the HDMI indicator will always be on when the video source input is normal off means no video source input The methods to obtain HDMI video streaming First connect the V40 Ground to the computer by WIFI or LAN port or...

Страница 68: ...2 168 168 1 and 2 19 13 addresses are reserved and cannot be used Let s take VLC software as an example the first step is to open the VLC software the second step is to open Network Streaming in Media as shown below The third step Enter the pull stream address note the V40 HDMI module is factory set with a default IP address of 192 168 168 13 Enter the following address rtsp 192 168 168 13 554 str...

Страница 69: ...e ground end 1 In order to have a better experience change the IP address of the IP camera to the same network segment 192 168 168 XX as the V40 This will allow you to access the serial port HDMI and LAN devices at the same time 2 After the IP address is changed the computer can choose to connect with the ground en by LAN cable or by WIFI After connection the computer also needs to be changed to t...

Страница 70: ...ayer here take VLC for example the first step to open the VLC software the second step in the media to open the network streaming as follows 4 Enter your IP camera video streaming address rtsp 192 168 168 20 554 user admin password channel 1 stream 0 sdp ...

Страница 71: ... of the RTSP service which can be changed in the network service of the device user admin Login username of the device password 密码空 empty channel 1 the first channel stream 0 sdp It is the main data rate 13 Video Link Parameters 13 1 V40 Video Link Parameters Frequency 2 304 2 390GHZ 2 402 2 482GHZ 2 500 2 570GHZ adjustable RF power 300mW Transmission range 10km grade LOS condition Depend on the e...

Страница 72: ...nas Dimension 116mm 69mm 31 5mm Frequency 800MHz 806 826MHz 1 4GHz 1427 91447 9MHz 2 4GHz 2401 5 2481 5MHz Modify in the software Bandwidth 3 20MHz adjustable Video input interface LAN port CODEC H 265 H 264 adjustable Video data rate 2 12Mbps adjustable Modulation OFDM Output power Max 25 dBm Data control interface UART 1 SBUS 2 Video definition 1080p60 max Antenna interface SMA Power supply volt...

Страница 73: ...t interface HDMI port CVBS port Cannot work simultaneously CODEC H 265 H 264 adjustable Data rate 2 12Mbps adjustable Modulation OFDM Output power Max 25 dBm Date control interface UART 1 SBUS 2 Video definition 1080p60 max HDMI port Type A Antenna interface SMA Power supply voltage 9 12V Recommend 3S battery power supply Weight 120g exclude antennas Dimension 364mm l 190mm w 95mm h Operating temp...

Страница 74: ... HID device controller please do not be confused you may be using the old hardware version of T20 or T21 that does not support HID function Pls refer to below to check HID usage Open T40 upper computer software Channel Configuration Comprehensive Configuration HID setting Set the channel enable and then close upper computer software 1 Open the control panel locate the device bar and click and ente...

Страница 75: ...www chinowing com 75 2 Enter Devices and printers 3 If there is a device called chinowing HZY JOY in the device list it means that your remote control has HID gamepad function If not it does not support ...

Страница 76: ...ect Game Controller Settings 5 Select chinowing HZY JOY click on properties and the user will see the individual channels in the test bar When you move the joystick the status of the corresponding channel will change The X Y axis Z axis X rotation Y rotation Z ...

Страница 77: ... currently only supports use with the Parameters Setting Software turned off 15 Firmware Upgrading Operation Steps Pls use the firmware upgrade tool to upgrade the firmware of the remote control and the receiver separately 15 1 T40 GCS Firmware Upgrade 1 Click on the official website to download the firmware select the appropriate version of the firmware and save it locally 2 Dial the joystick as ...

Страница 78: ... 4 At this time the serial port of firmware upgrade tool has been connected and the current hardware firmware and other information of the GCS are displayed as shown in the figure below 5 Click the search symbol to search out the datalink that have been linked on as T40 below Module ground Module Air ...

Страница 79: ... the folder symbol select the link file you want to upgrade as shown below to upgrade the T40 ground station 7 Click the Start menu to start the firmware upgrade the green progress bar at the bottom shows the progress of the upgrade ...

Страница 80: ...ver 4 The indicators RX and TX indicator light ON long enough to release the button 5 Open the upgrade software tool within 1 minute 6 After a successful connection it can be seen that the firmware upgrade tool serial port is connected and shows the current version of the receiver firmware and other information 7 Open the path to the firmware file you have just saved confirm that it is correct and...

Страница 81: ...y but there is no signal output Pls ensure whether ID Channel bandwidth of the receiver and remote control are the same 3 The receiver SBUS has signal output but the serial port cannot be connected or the transmission signal is garbled Please check that the baud rate of the serial port of the remote control and the receiver are the same and set it to the baud rate corresponding to the ground stati...

Страница 82: ...een 13 3inch 1920 1080 1000CCD top screen 12 1inch 1280 800 1500CCD bottom screen Remote control function Dual SBUS independent output able to control the vehicle and the payload simultaneously Human interface USB HID device CPU Intel i7 8565U 10500U Memory 8GB Operating system Win7 win10 Linux Storage 256GB SSD Serial port RS232 3 SBUS in out Network port WIFI Bluetooth 4G External interface USB3...

Отзывы: