
9
Technical data
9.1
Electric cable size
Attention
The voltage on the compressor terminals must not deviate more than 10% from the
nominal voltage.
It is however highly recommended to keep the voltage drop over the supply cables at
nominal current below 5% of the nominal voltage.
If cables are grouped together with other power cables, it may be necessary to use
cables of a larger size than those calculated for the standard operating conditions.
Use the original cable entry. See section
Dimension drawings
.
The compressor is delivered with 3 m (10 ft.) cable and a fitting cable gland.
This cable gland is necessary to ensure the protection degree of the electric cubicle and
to protect its components from dust from the environment.
Local regulations remain applicable if they are stricter than the values proposed below.
Power variant
7.5 kW
10 hp
11 kW
15 hp
15kW
20 hp
Frequency
(Hz)
Voltage
(V)
Cable Size
Cable Size
Cable Size
UL/cUL
60
208–230–460
AWG8/AWG10
AWG6/AWG10
AWG4/AWG8
60
575
AWG12
AWG10
AWG10
9.2
Settings for overload relay and fuses
7.5 kW
10hp
11 kW
15hp
15 kW
20hp
Frequency
(Hz)
Voltage
(V)
UL/cUL
Setting
overload
relay FM1
(A)
Main fuses
(class J or
RK) + Disc.
switch size
>= 1.25 x
FLA
Setting
overload
relay FM1
(A)
Main fuses
(class J or
RK) + Disc.
switch size
>= 1.25 x
FLA
Setting
overload
relay FM1
(A)
Main fuses
(class J or
RK) + Disc.
switch size
>= 1.25 x
FLA
60
DOL
208-230–
460
36.3-34.3–
16.9
50-45–25 A 48-45–22.5 60-60–35 A N/A
N/A
60
YD
208-230–
460
N/A
N/A
N/A
N/A
33.2-30–15 80-80–40 A
60
DOL
575
13
20 A
18.5
25 A
N/A
N/A
60
YD
575
N/A
N/A
N/A
N/A
12
30 A
Instruction book
76
2920 7114 70
Содержание QRS 10
Страница 2: ......
Страница 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Страница 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Страница 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Страница 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Страница 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Страница 84: ......
Страница 85: ......
Страница 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...