Step
Action
5
Regularly check the oil level. 10 to 15 minutes after stopping, the sight glass (SG)
should be between 1/4 and 3/4 full.
If the oil level is too low, stop the compressor, depressurise the oil system by
unscrewing oil filler plug (FC) one turn and wait a few minutes. Remove the plug and top
up the oil, until the sight glass is 3/4 full. Do not overfill. Fit and tighten plug (FC).
6
In automatic operation, the regulator is automatically controlling the compressor, i.e.
loading, unloading, stopping of the motors and restarting.
7
Regularly check the working pressure and the dew point (Units with dryer).
8
Regularly check that condensate is drained (Da) during operation.
5.3
Stopping
Condensate drain valve on air receiver
Control panel
Instruction book
58