Condensate drain valve on air receiver
Step
Action
1
Consult the installation instructions (see
Installation
).
2
Check that the electrical connections correspond to the local codes. The installation
must be earthed and protected against short circuits by fuses in all phases. An isolating
switch must be installed near the compressor.
3
Connect condensate drain valve (Dm) and automatic drain outlet (Da) to a drain
collector. Close the valve.
Connect condensate drain valve (4) of the air receiver to a drain collector. Close the
valve.
To drain the condensate, a NPT3/8 connection is available.
Connect a NPT3/4 valve to the air receiver port (2).
Oil system
Oil level sight-glass
Instruction book
54
2920 7114 70