6
Maintenance
6.1
Preventive maintenance schedule
Warning
Before carrying out any maintenance, repair work or adjustments, proceed as
follows:
• Stop the compressor.
• Switch off the voltage and open the isolating switch.
• Close the air outlet valve and open the manual condensate drain valves.
• Depressurise the compressor.
For detailed instructions, see the next sections.
The operator must apply all relevant
Safety precautions
.
Warranty-Product Liability
Use only authorised parts. Any damage or malfunction caused by the use of unauthorised parts
is not covered by Warranty or Product Liability.
General
When servicing, replace all removed gaskets, O-rings and washers.
Intervals
Carry out maintenance at the interval which comes first. The local Customer Centre may overrule
the maintenance schedule, especially the service intervals, depending on the environmental and
working conditions of the compressor.
The "longer interval" checks must also include the "shorter interval" checks.
Preventive maintenance schedule
Period (1)
Running hours
(1)
Operation
Daily
--
Check the oil level.
After stopping, drain the condensate from the air receiver by means
of the manual drain valve (4), see section
Stopping
.
3–monthly
500 (2)
Inspect the air filter. Clean if necessary.
“
2000
Check the tension and the condition of the belts. Adjust if necessary.
“
1000 (2)
Inspect the oil cooler. Clean if necessary.
“
“
For versions with dryer: inspect the condenser of the dryer. Clean if
necessary.
Yearly
2000
Replace the oil filter.
“
“
Replace the oil.
“
“
Replace the air filter.
“
4000 (2)
Replace the oil separator element.
“
4000
Replace the belts.
Instruction book
2920 7114 70
61
Содержание QRS 10
Страница 2: ......
Страница 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Страница 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Страница 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Страница 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Страница 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Страница 84: ......
Страница 85: ......
Страница 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...