
Replacing the drive belts
Step
Action
The belts (3) must be replaced as a set, even if only one of the belts is worn. Only use
genuine belts.
1
Stop the compressor, close the air outlet valve and switch off the voltage.
2
Remove the front door, the internal panel, the top cover, the pulley protection and the
left side panel.
3
Loosen the 4 bolts (2) by one turn.
4
Release the belt tension by loosening tensioning nut (1).
5
Remove the fan duct (4).
Remove the belts.
6
Install the new belts.
7
Tension belts (3) as described above.
8
Reassemble the fan duct (4), the pulley protection and the internal protection panel.
9
Reassemble left side and top panel cover.
10
Check the belt tension after 50 running hours.
Instruction book
2920 7114 70
71
Содержание QRS 10
Страница 2: ......
Страница 18: ...2 3 Oil system Oil system Oil system units with dryer Instruction book 16 2920 7114 70 ...
Страница 23: ...Electric cubicle UL DOL Instruction book 2920 7114 70 21 ...
Страница 51: ...208 230 460V 60Hz Instruction book 2920 7114 70 49 ...
Страница 74: ...8 Problem solving Control panel Air outlet valve Instruction book 72 2920 7114 70 ...
Страница 75: ...Oil filler plug Condensate drain valve on air receiver Instruction book 2920 7114 70 73 ...
Страница 84: ......
Страница 85: ......
Страница 86: ...No 2920 7114 70 2017 03 Printed in Belgium People Passion Performance www cp com ...