Instruction book
909935AIB
83
Condition
Fault
Remedy
Compressor air delivery or pressure
below normal.
Air consumption exceeds air
delivery of compressor.
Check equipment connected.
Choked air filters.
Replace filters.
Air leakage.
Check and correct.
Condition
Fault
Remedy
Compressor element outlet
temperature or delivery air
temperature above normal.
Oil level too low.
Check and correct.
Oil coolers clogged.
Consult the section Coolers.
Air cooler clogged.
Consult the section Coolers.
On air-cooled compressors,
insufficient cooling air or cooling
air temperature too high.
Check and correct as necessary.