Touch controller
3.1 Controller
The ES4000T Touch controller
Introduction
The controller has following functions:
• Controlling the unit
• Protecting the unit
• Monitoring components subject to service
• Automatic restart after voltage failure (ARAVF)
Automatic control of the unit
The controller maintains the net pressure between programmable limits by automatically loading
and unloading the unit (fixed speed units) or by adapting the motor speed (units with frequency
converter).
A number of programmable settings, e.g. the unloading and loading pressures (for fixed speed
units), the setpoint (for units with frequency converter), the minimum stop time, the maximum
number of motor starts and several other parameters are taken into account.
The controller stops the unit whenever possible to reduce the power consumption and restarts it
automatically when the net pressure decreases. If the expected unloading period is too short, the
unit is kept running to prevent too short standstill periods.
A number of time based automatic start/stop commands may be programmed. Take into
account that a start command will be executed (if programmed and activated), even after
manually stopping the unit.
Содержание CPF 300 A-8.6-60
Страница 1: ...People Passion Performance Instruction book ...
Страница 2: ......
Страница 17: ...Instruction book 909935AIB 15 Position of components Ghost view of air cooled CPF 300 A compressor ...
Страница 20: ...Instruction book 18 909935AIB 2 4 Regulating system Flow diagram ...
Страница 61: ...Instruction book 909935AIB 59 Electric cabinet Example of a cubicle for air cooled compressors ...
Страница 94: ......
Страница 117: ...No 2920 7119 80 2020 02 People Passion Performance www cp com ...