Instruction book
909935AIB
69
5.9 Use of air receiver
Instructions
Step
Action
1
This equipment can contain pressurised air and oil; be aware of its potential danger if
used improperly.
2
This equipment must only be used as compressed air/oil separator and must be
operated within the specified limits.
3
No alterations must be made to this equipment by welding, drilling, grinding or other
methods of mechanical working without written permission of the manufacturer. If there
is damage to a part under pressure from any cause, the complete part must be
replaced.
4
For the oil separator vessel: original bolts have to be used after opening for inside
inspection. The bolts must be removed and fitted with the correct tool. The bolts must be
tightened with a torque of 355 Nm (+/- 85 Nm). Damaged bolts must not be re-used. O-
rings must be replaced.
5
The safety valve is designed in such a way that the pressure will not permanently
exceed the maximum allowable operating pressure of the vessel, except for short
pressure surges up to 1.1 times the design pressure.
6
Only use oil specified by the manufacturer.
7
Make sure the vessel is fully depressurised before opening the drain plug or fill plug.
8
This vessel and other parts under pressure have been designed and built to guarantee
an operational lifetime in excess of 20 years and an infinite number of pressure load
cycles. A visual inspection (for damage, non-authorised alterations,...) of the vessel (at
the outside and inside) is recommended every 5 years. Make sure the vessel is fully
depressurised and isolated before carrying out an internal inspection.
9
At every inspection, also check the oil drain flexible. Replace if there is any wear or
damage.
Содержание CPF 300 A-8.6-60
Страница 1: ...People Passion Performance Instruction book ...
Страница 2: ......
Страница 17: ...Instruction book 909935AIB 15 Position of components Ghost view of air cooled CPF 300 A compressor ...
Страница 20: ...Instruction book 18 909935AIB 2 4 Regulating system Flow diagram ...
Страница 61: ...Instruction book 909935AIB 59 Electric cabinet Example of a cubicle for air cooled compressors ...
Страница 94: ......
Страница 117: ...No 2920 7119 80 2020 02 People Passion Performance www cp com ...