Instruction book
909935AIB
63
Procedure
Step
Action
1
Press the start button. The compressor starts running in unloaded condition. The
operation sign (4) lights up.
2
Approx. 10 seconds later (programmable), the compressor starts running loaded.
The status icon on the display of the controller changes from the running unloaded icon
to the running loaded icon.
5.4 During operation
Warning
The operator must apply all relevant
The operator should immediately stop the machine in case of oil leaks internally in the
machine as well as externally and consult a competent technician to resolve the cause.
The machine should not be restarted before the problem has been remedied.
The load cycle of the compressor must be limited to maximum two cycles per minute.
Description
Reference
Designation
Function
1
Touchscreen
Shows the compressor operating condition and a
number of icons to navigate through the menu.
The screen can be operated by touch.