S ec. 6Y -146
A. C. GENERATING SYSTEM (NON-INTEGRAL TYPE)
DRIVER AND POWER TRANSISTORS
(TR-1 AND T R -2), (Refer to Fig. 30)
If both readings in Step 1 are infinite, or if
both readings a re very high and identical, the tran
s is to r i s open. S im ilarly, if both readings in Step
2 a re infinite or very high and identical, the tran
s is to r is open.
REASSEMBLY AND FINAL CHECK
During a ssem b ly , coat with s ilic o n e g rea se
both sid e s of the flat in su lators used between the
tr a n sisto r s and heat sink, and a lso the heat sin k on
the sid e on which the tr a n sisto r s a re mounted. The
silic o n e g r e a se in c r e a se s heat conduction.
NON-INTEGRAL TYPE ALTERNATING CURRENT
GENERATOR SPECIFICATIONS
G E N E R A T O R M O D E L
1100842
1100849
1 1 1 7 7 5 4
1 1 1 7 7 5 6
M ake..................................................................................
S eries...................................................................................
T y p e ....................................................................................
Rotation (Viewing Drive En d )....................................................
Field Current at 80°F.
Am ps.................................................................................
V olts................................................................................
Cold Output at Specified Volts
Specified V o lts....................................................................
Amps.................................................................................
Generator RPM (Approx.).....................................................
Am ps.............. •...............................................................
Generator RPM (Approx.)......................................................
Rated Hot Output...................................................................
Delco-Remy
10DN
100
Clockwise
2
,
2
-
2.6
12
14
28
2000
40
5000
42
Delco-Remy
10DN
100
Clockwise
2
.
2
-
2.6
12
14
33
2000
58
5000
61
Delco-Remy
20DN
150
Clockwise
4.1-4
.6
12
14
20
*
1100
55*
2500
62
Delco-Remy
20DN
250
Clockwise
4.1-4
.6
12
14
20
*
1100
55*
2500
62
G E N E R A T O R M O D E L
1 1 1 7 7 8 1
1 1 1 7 7 8 7
M ake........................................................
Delco-Remy
20DN
Delco-Remy
20DN
Series..................................................................
T ype....................................................................................................
255
155
Rotation (Viewing Drive En d ).....................................................................
Clockwise
Clockwise
Brush Spring Tension (O z .).........................................................
Field Current at 80°F.
Amps..............................................................
41-4
6
4.1-4.6
12
Volts................................................................
12
Cold Output at Specified Volts
Specified V o lts..........................................................................
14
14
Amps....................................................................................
20
*
20
*
Generator RPM (Approx.)...............................................
1100
1100
Am ps...................................................
55*
55*
2500
Generator RPM (Approx.).....................................................................
2500
Rated Hot Output......................................................
62
62
*lf Generator Output is Checked Without a Regulator, Output Should Be 5-10% Higher Than Value Given.
**At Maximum Operating Speed.
TWO-UNIT TYP E VOLTAGE REGULATOR
M ake......................................................................
Delco-Remy
Delco-Remy
M odel.............................................................
1119507
1119515
Field Relay
Air Gap (In.) (a )................................................................
0.015
0.015
Point Opening ( I n .) ..............................................................
0.030
0.030
Closing Voltage Range..........................................................
3.8-7.2
1.5-3.2
Voltage Regulator
Air Gap (In.) (Approx.) (b ).....................................................
0.067
0.067
Point Opening ( I n .) .................................................................
0.014
0.014
Voltage C h art.......................................................................
No. 1
No. 1
(a) Tolerance Plus or Minus 20%
(b) Make Final Adjustment as Per Text
CHEVROLET SERIES 70-90 HEAVY DUTY TRUCK SHOP MANUAL SUPPLEMENT
Содержание DB90 Series
Страница 1: ...HEAVY DUTY TRUCK SUPPLEMENT...
Страница 8: ...Sec 0 2 LUBRICATION Figure 1 Lubrication Chart Conventional Cab M odels...
Страница 10: ...Sec 0 4 LUBRICATION CHEVROLET SERIES 70 90 HEAVY DUTY TRUCK SHOP MANUAL SUPPLEMENT...
Страница 12: ...Sec 0 6 LUBRICATION CHEVROLET SERIES 70 90 HEAVY DUTY TRUCK SHOP MANUAL SUPPLEMENT...
Страница 14: ...Sec 0 8 LUBRICATION CHEVROLET SERIES 70 90 HEAVY DUTY TRUCK SHOP MANUAL SUPPLEMENT...
Страница 241: ......
Страница 242: ...m m...