Smart Dry Contact Switch 7 - Operating Instructions
14
Association group management
This section defines the configuration parameters associated respectively with the control groups G1, G2, and dimming.
Parameter
Number
Size
Parameter Name
Default
Value
Description
40
1
G1_SETUP
1
Define which events on the input control G1 association
group.
Parameters Values Min: 0 Max: 31
Value
Description
0
No control
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default value: 1 click
→
1
Parameter
Number
Size
Parameter Name
Default
Value
Description
41
1
G2_ SETUP
2
Define which events on the input control G2 association
group.
Parameters Values Min: 0 Max: 31
Value
Description
0
No control
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If more than 1 event are supported, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3