Output Configuration:
Parameter
Number
Size
Parameter Name
Default
Value
Description
21
1
OUT_TYPE
0
Define the output type.
Parameters Values Min: 0 Max: 1
Value
Description
0
direct load or normally Open relay
1
normally Closed relay
Parameter
Number
Size
Parameter Name
Default
Value
Description
23
1
STARTUP_OUT
2
Define the output level on startup
(
status of the device following a restart
)
Parameters Values Min: 0 Max: 3
Value
Description
0
OFF
1
ON
2
Previous status
3
equal to input (ON if input close, OFF if input open)
Timer management
It allows you to activate an ON and OFF timer independently. To activate the timers you need to:
1) Define which event will start the timer (Parameter 30)
2) To set the Off timer define the time with parameter 31
3) To set the On timer define the time with parameter 32
Parameter
Number
Size
Parameter Name
Default
Value
Description
30
1
TIMER_SETUP
0
Define which trigger events activate the timers when
output status
has changed
Parameters Values Min: 0 Max: 127
Value
Description
0
disabled
1
1 click