Smart Dry Contact Switch 7 - Operating Instructions
11
Parameter
Number
Size
Parameter Name
Default
Value
Description
11
1
IN_ON_EXCLUSION
0
Define which events on the input do not switch-On output.
Parameters Values Min: 0 Max: 31
Value
Description
0
Disable
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable
→
0
Parameter
Number
Size
Parameter Name
Default
Value
Description
12
1
IN_OFF_EXCLUSION
0
Define which events on the input do not switch-Off output.
Parameters Values Min: 0 Max: 31
Value
Description
0
Disable
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: Disable
→
0