Smart Dry Contact Switch 7 - Operating Instructions
10
Configurations
Input Configuration
Parameter
Number
Size
Parameter Name
Default
Value
Description
1
1
IN_TYPE
1
Define the input type
Parameters Values Min: 0 Max: 2
Value
Description
0
no switch input
1
momentary switch (button)
2
toggle switch
Parameter
Number
Size
Parameter Name
Default
Value
Description
10
1
IN_TOGGLE
15
Define which event on the input 1 toggle output.
Parameters Values Min: 0 Max: 31
Value
Description
0
Disabled
1
1 click
2
2 clicks
4
3 clicks
8
Hold down
16
Up
If you support more than 1 event, the value for the configuration parameter is the sum of the event values.
For example:
1 click and 2 clicks -> Parameter value must be 1 + 2 =3
1 click and 3 clicks -> Parameter value must be 1 + 4 =5
Default Value: 1 click, 2 clicks, 3 clicks, Hold down
→
15