background image

 
 
 
 

EZpar™ 64 RGBA User Manual 

Page 3 of 20 

1.

 

B

EFORE 

Y

OU 

B

EGIN

 

 

 

What Is 

Included

 

  EZpar™ 64 RGBA 

  Infrared Remote Control (IRC) 

  Power Cord 

  Warranty Card 

  Quick Reference Guide 

 

 

Unpacking 

Instructions

 

Carefully unpack the product immediately and check the container to make sure all the 
parts are in the package and are in good condition. 

 

 

Claims 

If the box or the contents (the product and included accessories) appear damaged from 
shipping, or show signs of mishandling, notify the carrier immediately, not CHAUVET®. 
Failure to report damage to the carrier immediately may invalidate your claim.  In 
addition, keep the box and contents for inspection. 

For other issues, such as missing components or parts, damage not related to shipping, 
or concealed damage, file a claim with CHAUVET® within 7 days of delivery. 

 

 

Text 

Conventions

 

Convention 

Meaning 

1–512 

A range of values 

50/60 

A set of values of which only one can be chosen 

Settings 

A menu option not to be modified  

Menu > Settings 

A sequence of menu options to be followed 

<ENTER> 

A key to be pressed on the product’s control panel 

ON 

A value to be entered or selected 

 

 

Symbols 

Symbol 

Meaning 

 

Critical installation, configuration, or operation information. Not 
following these instructions may make the product not work, cause 
damage to the product, or cause harm to the operator. 

 

Important installation or configuration information. The product 
may not function correctly if this information is not used. 

 

Useful information. 

 

 

Disclaimer

 

The information and specifications contained in this User Manual are subject to change 
without notice. CHAUVET® assumes no responsibility or liability for any errors or 
omissions,  and  reserves the right to revise or recreate  this manual at any time. 
Download the latest version from 

www.chauvetlighting.com

© Copyright 2013 CHAUVET®. All rights reserved. 

Electronically published by CHAUVET® in the United States of America. 

 

 

 

Author 

Date 

Editor 

Date 

 

Albert Leon 

06/12/13 

T. Yeago 

06/20/13 

 

 

Содержание EZpar 64 RGBA

Страница 1: ...User Manual ...

Страница 2: ...Fuse Replacement 8 Power Linking 9 Mounting 10 Orientation 10 Rigging 10 4 Operation 11 Control Panel Operation 11 Menu Map 11 Configuration DMX 12 Starting Address 12 DMX Channel Modes Assignments and Values 13 8 Channel 13 4 Channel 13 Configuration Standalone 14 Sound Active Mode 14 Sound Sensitivity 14 Auto Programs 14 Program Speed 14 Static Colors 15 Custom Color Mixing 15 Infrared Sensor 15...

Страница 3: ...lues of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the prod...

Страница 4: ...sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilati...

Страница 5: ...l Page 5 of 20 2 INTRODUCTION Overview Menu Buttons Power In Fuse Holder Menu Display DMX Out DMX In Power Out Power Switch Microphone Battery Charged Green Indicator Light Battery Charging Red Indicator Light Back Panel View ...

Страница 6: ...Page 6 of 20 EZpar 64 RGBA User Manual Dimensions 10 8 in 276 mm 10 8 in 275 mm 2 6 in 66 mm ...

Страница 7: ...rgeable lithium battery for cable free operation To charge the battery simply plug in the power cord at any time before during or after operation To charge the battery before or after operation with all the LEDs off leave the power switch in the Off position The red indicator light for the battery turns on while the battery is charging The green indicator light turns on when the battery is done ch...

Страница 8: ...river into the slot of the fuse holder 3 Pry the fuse holder out of the housing 4 Remove the blown fuse from the holder 5 Replace with a fuse of the exact same type and rating 6 Insert the fuse holder back in place and reconnect power A spare fuse is not included however the safety cap has room for a spare Installed fuse held by plastic clip Spare fuse holder inside safety cap Safety cap ...

Страница 9: ...ar 64 RGBA units on 120 VAC or up to 85 EZpar 64 RGBA units on 230 VAC The power linking diagram shown above corresponds to the North American version of the product ONLY If using the product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region 1 st Product 2nd Product 3 rd Product Additional Products...

Страница 10: ... to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach The bracket a...

Страница 11: ...d512 4 channel DMX mode RGBA 8 CH 8 channel DMX mode C C 1 Red Preset static colors C 2 Green C 3 Blue C 4 Amber C 5 Cyan C 6 Magenta C 7 Yellow C 8 White RGB C 9 Orange C 10 Light Green C 11 Violet C 12 Yellow C 13 Pink C 14 Light Blue C 15 White RGBA P P 1 4 color program switching P 2 4 color program fading P 3 15 color program switching P 4 15 color program fading P 5 4 color program sound act...

Страница 12: ...u choose a starting address that is too high you could restrict the access to some of the product s channels The EZpar 64 RGBA uses up to 8 DMX channels in its 8 channel DMX mode which defines the highest configurable address to 505 If unfamiliar with DMX download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press MENU repeatedly until 4 CH for the ...

Страница 13: ...hannel 7 is 032 223 000 ó 255 Slow to fast Strobe 000 ó 015 016 ó 255 No function Slow to fast 7 Mode 000 ó 031 032 ó 063 064 ó 095 096 ó 127 128 ó 159 160 ó 191 192 ó 223 224 ó 255 No function Pulse effect 0 100 Pulse effect 100 0 Pulse effect 100 0 100 Auto fade transition Auto snap transition 4 colors Auto snap transition 15 colors Sound Active mode 8 Dimmer 000 ó 255 0 100 4 Channel Channel Fu...

Страница 14: ... below 4 Press ENTER Sound Sensitivity To set the sound sensitivity follow the instructions below 1 Press MENU repeatedly until SenS shows on the display 2 Use UP or DOWN to select the desired sound sensitivity u 0 u100 3 Press ENTER The product will only respond to low frequencies of music bass and drums Auto Programs To select an auto program do the following 1 Press MENU repeatedly until P show...

Страница 15: ...and one of the following colors shows on the display rXXX red gXXX green bXXX blue or AXXX amber 3 Press ENTER repeatedly to select the desired color 4 Use UP or DOWN to select the desired color value 0 100 NOTE Selecting 0 will turn the color off 5 Press ENTER to select color value and continue to the next color 6 Repeat steps 3 to 5 until you create your desired color Infrared Remote Control The...

Страница 16: ...fic color with the IRC 1 Press MANUAL on the IRC 2 Press any number between 0 9 to choose your color 0 white RGBA 1 red 2 amber 3 yellow 4 green 5 cyan 6 blue 7 magenta 8 orange and 9 amber To manually control the RGB percentage 1 Press MANUAL on the IRC 2 Press R G or B to choose your color 3 Press or to increase or decrease the percentage of each color Miscellaneous Operation To adjust the strob...

Страница 17: ...ity shows on the display 2 Press ENTER to accept 3 Set the DMX address to d 1 4 Connect the DMX input of the first slave unit to the DMX output of the master unit 5 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 6 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either auto program or Sound Active mo...

Страница 18: ...until the product is at room temperature Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents and reachable internal components Clean all external optics and glass transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue ...

Страница 19: ...Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan LED 0 25 W 100 000 hours Color Quantity Current Red 45 20 mA Green 45 20 mA Blue 45 20 mA Amber 45 20 mA Photo Optic Parameter Illuminance 2 m 1325 lx Beam angle 14º Field angle 23º Battery Parameter All Colors On Single Color On Maximum run time...

Страница 20: ... number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Name Address Phone number RMA number Description of the problem Be sure to pack the product properly Any shipping dam...

Отзывы: