background image

 
 
 
 

Page 20 of 20 

EZpar™ 64 RGBA User Manual 

 

To return a product or request support: 

  In the U.S., contact CHAUVET® World Headquarters (see below). 

  In the UK or Ireland, contact CHAUVET® Europe Ltd. (see below). 

  In any other country, DO NOT contact CHAUVET®. Contact your distributor. See 

www.chauvetlighting.com

 for distributors outside the U.S., United Kingdom, or 

Ireland. 

 

 

 

If you live outside the U.S., United Kingdom, or Ireland, contact your distributor of 
record and follow their instructions on how to return CHAUVET® products to 
them. Visit our website for contact details. 

 

 

Returns 

Call the corresponding CHAUVET®  Technical  Support office and request a Return 
Merchandise Authorization (RMA) number before shipping the product. Be prepared to 
provide the model number, serial number, and a brief description of the cause for the 
return. 

You must send the merchandise prepaid, in its original box, and with its original packing 
and accessories. CHAUVET® will not issue call tags. 

Clearly label the package with the RMA number. CHAUVET®  will refuse any product 
returned without an RMA number. 

 

 

 

Write the RMA number on a properly affixed label. DO NOT write the RMA number 
directly on the box. 

 

 

 

Before sending the product,  clearly write the following information on a piece of paper 
and place it inside the box: 

 

Name 

 

Address 

 

Phone number 

 

RMA number 

 

Description of the problem 

Be sure to pack the product  properly. Any shipping damage resulting from inadequate 
packaging will be your  responsibility.  FedEx  packing or double-boxing  are 
recommended. 

 

 

 

CHAUVET®  reserves the right to use its own discretion to repair or replace 
returned product(s). 

 

 

Contact Us

 

World Headquarters 

CHAUVET® 

General Information

 

Address: 

5200 NW 108th Avenue 

 

Sunrise, FL 33351 

Voice:  

(954) 577-4455 

Fax:  

(954) 929-5560 

Toll free:  

(800) 762-1084 

United Kingdom & Ireland 

CHAUVET® Europe Ltd. 

General Information 

 

Address:  

Unit 1C 

 

Brookhill Road Industrial Estate 

 

Pinxton, Nottingham, UK 

 

NG16 6NT 

Voice:  

+44 (0)1773 511115 

Fax:  

+44 (0)1773 511110 

 

Technical Support

 

Voice:  

(954) 577-4455 (Press 

4

Fax:  

(954) 756-8015 

Email:  

[email protected]

  

Technical Support

 

Email:  

[email protected]

  

 

 

World Wide Web 

 

www.chauvetlighting.com

  

World Wide Web 

 

www.chauvetlighting.co.uk

  

 

Содержание EZpar 64 RGBA

Страница 1: ...User Manual ...

Страница 2: ...Fuse Replacement 8 Power Linking 9 Mounting 10 Orientation 10 Rigging 10 4 Operation 11 Control Panel Operation 11 Menu Map 11 Configuration DMX 12 Starting Address 12 DMX Channel Modes Assignments and Values 13 8 Channel 13 4 Channel 13 Configuration Standalone 14 Sound Active Mode 14 Sound Sensitivity 14 Auto Programs 14 Program Speed 14 Static Colors 15 Custom Color Mixing 15 Infrared Sensor 15...

Страница 3: ...lues of which only one can be chosen Settings A menu option not to be modified Menu Settings A sequence of menu options to be followed ENTER A key to be pressed on the product s control panel ON A value to be entered or selected Symbols Symbol Meaning Critical installation configuration or operation information Not following these instructions may make the product not work cause damage to the prod...

Страница 4: ...sure that the voltage of the outlet to which you are connecting the product is within the range stated on the decal or rear panel of the product The product is for indoor use only IP20 To prevent risk of fire or shock do not expose the product to rain or moisture Always install the product in a location with adequate ventilation at least 20 in 50 cm from adjacent surfaces Be sure that no ventilati...

Страница 5: ...l Page 5 of 20 2 INTRODUCTION Overview Menu Buttons Power In Fuse Holder Menu Display DMX Out DMX In Power Out Power Switch Microphone Battery Charged Green Indicator Light Battery Charging Red Indicator Light Back Panel View ...

Страница 6: ...Page 6 of 20 EZpar 64 RGBA User Manual Dimensions 10 8 in 276 mm 10 8 in 275 mm 2 6 in 66 mm ...

Страница 7: ...rgeable lithium battery for cable free operation To charge the battery simply plug in the power cord at any time before during or after operation To charge the battery before or after operation with all the LEDs off leave the power switch in the Off position The red indicator light for the battery turns on while the battery is charging The green indicator light turns on when the battery is done ch...

Страница 8: ...river into the slot of the fuse holder 3 Pry the fuse holder out of the housing 4 Remove the blown fuse from the holder 5 Replace with a fuse of the exact same type and rating 6 Insert the fuse holder back in place and reconnect power A spare fuse is not included however the safety cap has room for a spare Installed fuse held by plastic clip Spare fuse holder inside safety cap Safety cap ...

Страница 9: ...ar 64 RGBA units on 120 VAC or up to 85 EZpar 64 RGBA units on 230 VAC The power linking diagram shown above corresponds to the North American version of the product ONLY If using the product in other markets you must consult with the local CHAUVET distributor as power linking connectors and requirements may differ in your country or region 1 st Product 2nd Product 3 rd Product Additional Products...

Страница 10: ... to a rigging point such as an elevated platform or a truss When rigging the product onto a truss you should use a mounting clamp of appropriate weight capacity The bracket has a 13 mm hole which is appropriate for this purpose When power linking multiple products you must always consider the length of the power linking cable and mount the products close enough for the cable to reach The bracket a...

Страница 11: ...d512 4 channel DMX mode RGBA 8 CH 8 channel DMX mode C C 1 Red Preset static colors C 2 Green C 3 Blue C 4 Amber C 5 Cyan C 6 Magenta C 7 Yellow C 8 White RGB C 9 Orange C 10 Light Green C 11 Violet C 12 Yellow C 13 Pink C 14 Light Blue C 15 White RGBA P P 1 4 color program switching P 2 4 color program fading P 3 15 color program switching P 4 15 color program fading P 5 4 color program sound act...

Страница 12: ...u choose a starting address that is too high you could restrict the access to some of the product s channels The EZpar 64 RGBA uses up to 8 DMX channels in its 8 channel DMX mode which defines the highest configurable address to 505 If unfamiliar with DMX download the DMX Primer from www chauvetlighting com To select the starting address do the following 1 Press MENU repeatedly until 4 CH for the ...

Страница 13: ...hannel 7 is 032 223 000 ó 255 Slow to fast Strobe 000 ó 015 016 ó 255 No function Slow to fast 7 Mode 000 ó 031 032 ó 063 064 ó 095 096 ó 127 128 ó 159 160 ó 191 192 ó 223 224 ó 255 No function Pulse effect 0 100 Pulse effect 100 0 Pulse effect 100 0 100 Auto fade transition Auto snap transition 4 colors Auto snap transition 15 colors Sound Active mode 8 Dimmer 000 ó 255 0 100 4 Channel Channel Fu...

Страница 14: ... below 4 Press ENTER Sound Sensitivity To set the sound sensitivity follow the instructions below 1 Press MENU repeatedly until SenS shows on the display 2 Use UP or DOWN to select the desired sound sensitivity u 0 u100 3 Press ENTER The product will only respond to low frequencies of music bass and drums Auto Programs To select an auto program do the following 1 Press MENU repeatedly until P show...

Страница 15: ...and one of the following colors shows on the display rXXX red gXXX green bXXX blue or AXXX amber 3 Press ENTER repeatedly to select the desired color 4 Use UP or DOWN to select the desired color value 0 100 NOTE Selecting 0 will turn the color off 5 Press ENTER to select color value and continue to the next color 6 Repeat steps 3 to 5 until you create your desired color Infrared Remote Control The...

Страница 16: ...fic color with the IRC 1 Press MANUAL on the IRC 2 Press any number between 0 9 to choose your color 0 white RGBA 1 red 2 amber 3 yellow 4 green 5 cyan 6 blue 7 magenta 8 orange and 9 amber To manually control the RGB percentage 1 Press MANUAL on the IRC 2 Press R G or B to choose your color 3 Press or to increase or decrease the percentage of each color Miscellaneous Operation To adjust the strob...

Страница 17: ...ity shows on the display 2 Press ENTER to accept 3 Set the DMX address to d 1 4 Connect the DMX input of the first slave unit to the DMX output of the master unit 5 Connect the DMX input of the subsequent slave units to the DMX output of the previous slave unit 6 Finish setting and connecting all the slave units Master unit 1 Set the master unit to operate in either auto program or Sound Active mo...

Страница 18: ...until the product is at room temperature Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external surface vents and reachable internal components Clean all external optics and glass transparent surfaces with a mild soap solution ammonia free glass cleaner or isopropyl alcohol Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue ...

Страница 19: ...Worldwide UK Europe Power input connector IEC IEC Power output connector Edison IEC Power Cord plug Edison US Local plug Light Source Type Power Lifespan LED 0 25 W 100 000 hours Color Quantity Current Red 45 20 mA Green 45 20 mA Blue 45 20 mA Amber 45 20 mA Photo Optic Parameter Illuminance 2 m 1325 lx Beam angle 14º Field angle 23º Battery Parameter All Colors On Single Color On Maximum run time...

Страница 20: ... number CHAUVET will refuse any product returned without an RMA number Write the RMA number on a properly affixed label DO NOT write the RMA number directly on the box Before sending the product clearly write the following information on a piece of paper and place it inside the box Name Address Phone number RMA number Description of the problem Be sure to pack the product properly Any shipping dam...

Отзывы: