Straight
6
Outdoor gas appliance is not intended to be installed in
or on a boat.
Outdoor gas appliance is not intended to be installed in
or on an RV.
Never attempt to attach this grill to the self-contained LP
gas system of a camper trailer or motor home.
Do not use grill until leak-tested.
If a leak is detected at any time,
STOP
and call the fire
department.
If you cannot stop a gas leak
IMMEDIATELY
close LP
cylinder valve and call LP gas supplier or your fire
department!
WARNING
DANGER
Do not insert any tool or foreign object into the valve outlet
or safety relief valve. You may damage the valve and
cause a leak. Leaking propane may result in explosion,
fire, severe personal injury, or death.
Hold coupling nut and regulator
as shown for proper connection
to LP cylinder valve.
Connecting Regulator to the LP Cylinder (Con’t.)
6. Turn the coupling nut clockwise and tighten to a
Full Stop
.
The regulator will seal on the back-check feature in the LP
cylinder valve, resulting in some resistance.
An additional
one-half to three-quarters turn is required to complete the
connection. Tighten by hand only - do not use tools.
NOTE:
If you cannot complete the connection, disconnect regulator and
repeat steps 5 and 6. If you are still unable to complete the
connection,
do not use this regulator!
Never remove threaded orifice
at end of valve during leak
testing of valves.
Leak Testing Valves, Hoses and Regulator
1.
Turn all control knobs to the OFF position.
2. Be sure regulator is tightly connected to LP cylinder.
3. Completely open LP cylinder valve by turning hand wheel
counterclockwise. If you hear a
rushing sound
, turn gas off
immediately. There is a major leak at the connection.
Correct
before proceeding.
4. Brush soapy solution onto areas circled below.
5. If “growing” bubbles appear there is a leak. Close LP cylinder
valve immediately and retighten connections. If leaks cannot
be stopped do not try to repair. Call for replacement parts.
Order new parts by giving the serial, model number and name
and part number of items needed (see parts list) to the Grill
Service Center at 1-888-430-7870.
6. Always close LP cylinder valve after performing leak test by
turning hand wheel clockwise.