G- and K-Series User’s Guide
6-4
To enable dynamic spares:
1
From the System Menu, select
Configuration Menu
and press
Enter
.
The Configuration Menu screen displays.
2
Select
Option Configuration
and press
Enter
.
The Option Configuration screen displays.
3
Select
Dynamic Spare Configuration
and press
Enter
.
The Dynamic Spare Config screen displays. The current setting is marked with
an * next to it.
4
Select
Enabled
and press
Enter
.
The Rescan Rate screen displays.
5
Enter the rescan rate in minutes.
This tells the controller how often it should look for an available drive by
rescanning the bus. Remember that rescanning the bus frequently can affect
performance. If you have a SEP, the dynamic spare configuration will not
rescan the bus. The SEP will detect the new drive and tell the controller to
rescan and the rescan rate you set here will not affect the system.
The system confirms the change.
6
Select
Yes
and press
Enter
.