TROUBLESHOOTING
Perform the seven checks listed below in the event that your dishwasher does not operate
as expected.
1. All switches are ON
2. Wash and rinse nozzles are clean
3. Wash and rinse pipe assemblies are installed correctly
4. Scrap screens are properly positioned
5. Thermostat(s) are properly adjusted
6. Detergent and rinse additive dispensers are adequately filled
If a problem still exists, use the following table for troubleshooting
CONDITION
CAUSE
SOLUTION
Machine will not start
Doors not closed ....................................
Make sure doors are fully closed
Door safety switch faulty ......................
Contact your service agency
Main switch off ......................................
Check disconnect at main panel
Blown Fuse ..........................................
Replace fuse
Machine washes
Timer or door switch defective ............
Contact your service agency
constantly
Low or no water
Main water supply is turned off ............
Turn on house water supply
Faulty drain valve ..................................
Turn off power at main switch, pull
lever on valve to drain. Contact your
service agency
Machine doors not fully closed ............
Close doors securely
Faulty fill valve ......................................
Contact your service agency
Machine not filled initially ....................
Push Power switch UP to fill
Clogged strainer in fill valve ................
Clean or replace
Stuck or defective float ..........................
Check floats and clean
Continuous water filling
Defective Circuit Board ........................
Contact your service agency
Fill valve will not close..........................
Clean or replace
Drain valve will not close ......................
Replace drain valve/contact your
service agency
Stuck or Defective float switch..............
Inspect or replace float switch
Wash motor not running
Overload protector tripped ....................
Reset overload in Control Box
Defective motor ....................................
Contact your service agency
Wash tank water
Incoming water temperature ..................
Raise temperature to:
temperature is low
at machine too low
110-140˚F/43-60˚C for D-HBT
when in use
180˚F/82˚C for D-H1T
Defective thermometer.........................
Check or replace
Defective thermostat ..............................
Check for proper setting
or replace
Defective heater element ......................
Check or replace
Defective solenoid valve ........................
Check or replace
Heater elements ....................................
Clean and delime
have soil/lime buildup
20