Water Connections (Cont.)
2. A manual shut-off valve for steam and water (supplied by others) should be installed in
the supply line to allow for servicing of the machine. The shut-off valve should be the
same size or larger than the supply line.
3. Install a 3/4" pressure reducing valve (PRV) in the water supply line if flow pressure
exceeds 20-22 PSI/138-151.8 kPa.
A PRV is standard equipment on Model D-HBT. A PRV is not standard equipment on
Models D-H1T.
Drain Connections
1. All models are GRAVITY DRAIN machines equipped with a 2" O.D. hose connection
point.
2. The maximum drain flow rate is 15 gallons/min-56.8 liters/min.
3. Drain height for all models must not exceed 8-7/8" (225mm) above floor level.
4. The drain connection is made to the dishwasher from underneath the machine through
an access hole in the machine base.
Ventilation
NOTE:
Ventilation must comply with local sanitary and plumbing codes.
CAUTION:
Exhaust air should not be vented into a wall, ceiling, or concealed space of a building.
Condensation can cause damage.
8
INSTALLATION
!