575V Only
Three Phase
480V
Three Phase - High Voltage
208-240V
Three Phase - Low Voltage
Figure 17
Pump Motor Wiring Diagrams
Single Phase - High Voltage
Single Phase - Low Voltage
ELECTRICAL SERVICE (Cont.)
Motor Connections —
1. Models D-HBT and D-H1T are available in either single phase or 3 phase voltages.
2.
Motor rotation was set at the factory. For three phase machines, reversing the motor direction
is done in the control cabinet by reversing the wires L1 and L2 on the disconnect side of the
main electrical connection block. For single phase machines, motor rotation is changed at the
motor connection plate on the rear of the single phase motor (if necessary).
Refer to Fig. 17 for the proper wiring of the pump motor for single and three phase voltages.