56
Dual Gate Settings
NOTE:
We recommend that all accessories and board configurations are set on the primary operator.
Main control board
FEATURE
PRIMARY OPERATOR
SECONDARY OPERATOR
Timer-to-
Close
Set the TTC dial to desired
setting
OFF
Bi-Part
Delay
Switch
Synchronized Close: ON
Synchronized Close: ON
Speed
Set the speed control dial on each operator to the desired
setting, see
for more details
Expansion board
FEATURE
PRIMARY OPERATOR
SECONDARY
OPERATOR
QUICK CLOSE Switch
ON
OFF
ANTI-TAIL Switch
ON
OFF
LOW BATT Switch
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
Battery Fail OPEN:
OPEN
Battery Fail CLOSE:
CLOSE
AC FAIL OPEN/BATT
Switch
OPEN
OPEN
Accessories
ACCESSORY
PRIMARY OPERATOR
SECONDARY
OPERATOR
Remote Controls
Program remote
controls 1 to 50 to the
primary operator.
Program remote
controls 51 to 100 to the
secondary operator
LiftMaster Internet
Gateway
Program to primary
operator.
Garage and Gate
Monitor
Program to primary
operator.
APPENDIX