APPENDIX A
SYSTEM OPERATION REFERENCE
CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTS
For control and indicator locations, refer to Figure 11. For detailed explanations of the Gate
Operator's various, controls, indicators, inputs and adjustments, refer to the following pages.
CONTROLS
KEYPAD
The 12-key keypad is used for local operation, programming and
service.
SWITCH S2
GATE OPEN TO Selects the direction the gate will open (LEFT/RIGHT).
LEFT/RIGHT
SWITCH S3
LOW BATTERY Selects the direction the gate will move and remain when the LOW
LEFT/RIGHT
BATTERY input is activated by an Uninterruptible Power Supply (UPS).
INDICATORS
LED indicators light when controls and inputs are active. Additional indicators are as follows:
DISPLAY
This is a seven segment character display that gives numerical
response to service personnel during programming and operation.
LEFT LIMIT
Indicates that the LEFT limit switch is activated.
RIGHT LIMIT
Indicates that the RIGHT limit switch is activated.
MTR LEFT
Indicates the gate is moving to the left.
MTR RIGHT
Indicates the gate is moving to the right.
RECV
Indicates data is being received from the other unit in a Master/
Slave system.
XMIT
Indicates data is being sent to the other unit in a Master/Slave
system.
OFF HOOK
Indicates the gate operator is off hook and using the phone line.
OBSTRUCTION
Indicates the peak or average motor current threshold was reached
and the motor was stopped. See Fault List.
INTERRUPT BAR
Indicates Interrupt Bar (Edge Sensor) switch was activated
(EDGE SENSOR)
and the motor was stopped.
OPEN MTR
Indicates the motor is engaged, but is not drawing any current. The
thermal overload switch on the motor may need to be reset. See
Fault List.
STUCK LIMIT
Indicates that a limit switch is stuck closed.
MAX RUN TIME
Indicates the motor ran for 75 seconds without reaching a limit switch
and was stopped. Usually requires mechanical service. See Fault
List.
LINE
Indicates an incoming telephone call ring detect and whether the
phone line is available when the gate operator wants to initiate a call.
MAG LOCK
Indicates the MagLock is engaged.
OBSTRUCTION
Indicates the Obstruction Alarm has sounded after two
ALARM
consecutive gate obstruction faults.