5.0 Installation & Setup
14
5.4.6 Attaching the Electric Eyes
Make sure power is disconnected from the machine. If necessary, connect the wires to the power
panel. Attach electric eye assemblies with provided hardware, making sure that the bottom of the
electric eye housings are parallel to the table. Once power is hooked up, the electric eyes should be
checked for alignment. See the Titan 230 Technical Service and Parts manual for information on how
to do this.
5.4.7 Attaching the Side Tables
Using (4) 3/8-16 cap screws and washers, attach the table supports to the under side of the main
table (Figure 10), making sure to route each cut button cable through the slots in the brackets. Lay
the side tables on top of the support brackets and insert the mounting hardware. Slide the table
extension tight to the table and tighten the hardware.
View from underneath table
Figure 10
5.5 Hydraulic System Check
The cutting/clamping mechanism of the Titan 230 is powered by a hydraulic system consisting of an
electric motor coupled directly to a hydraulic pump.
The hydraulic reservoir holds 4 quarts (1 gallon) of hydraulic fluid. It is filled with Rykon 100 hydraulic
fluid at the factory but should be checked before operation. Remove the lower rear panel cover and
unscrew the cap on top of the tank (Figure 11 on page 15
). Fluid level should be at 1/8” from the end
of the dip stick (check with dip stick cap screwed in). Add fluid if necessary but avoid overfilling as
this could cause leakage when hot. Replace the rear panel when finished. For more information
about checking and changing the hydraulic fluid, including a cross-reference chart of approved fluids,
see the Titan230 Technical Service and Parts manual.
The hydraulic fluid should be checked weekly and changed
AT LEAST ONCE-A-YEAR
or after every
1,000 hours of operation.