14
4
Mounting
Electrical installation
Connection to the 230 V system
4.3.1.3
Terminal data
Mains connection
Motor connection
Inverter
VS10231P7
VS10232P4
VS10233P2
VS10234P2
VS10236P0
VS10237P0
VS10239P6
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Connection
X105
Connection type
Screw terminal
Min. cable cross-section
mm²
1
Max. cable cross-section
mm²
2.5
Stripping length
mm
8
Tightening torque
Nm
0.5
Required tool
0.5 x 3.0
PE conductor connection
Inverter
VS10231P7
VS10232P4
VS10233P2
VS10234P2
VS10236P0
VS10237P0
VS10239P6
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Connection
PE
Connection type
PE screw
Min. cable cross-section
mm²
1
Max. cable cross-section
mm²
6
Stripping length
mm
10
Tightening torque
Nm
1.2
Required tool
0.8 x 5.5
Control connections
Terminal description
Relay output
Control terminals
Connection
X9
X3
Connection type
Screw terminal
Spring terminal
Min. cable cross-section
mm²
0.5
0.5
Max. cable cross-section
mm²
1.5
1.5
Stripping length
mm
6
9
Tightening torque
Nm
0.2
-
Required tool
0.4 x 2.5
0.4 x 2.5
Inverter
VS10231P7
VS10232P4
VS10233P2
VS10234P2
VS10236P0
VS10237P0
VS10239P6
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Connection
X100
Connection type
Screw terminal
Min. cable cross-section
mm²
1
Max. cable cross-section
mm²
2.5
6
Stripping length
mm
8
Tightening torque
Nm
0.5
0.7
Required tool
0.5 x 3.0
0.6 x 3.5
Содержание Emotron VS10 Series
Страница 1: ...Emotron VS10 VS30 AC drive 0 25 2 2 kW Mounting and switch on instruction ...
Страница 2: ...Diese Seite wurde absichtlich leer gelassen ...
Страница 10: ...10 4 Mounting Mechanical installation Dimensions VS10 VS30 0 55 kW 0 75 kW All dimensions in mm ...
Страница 11: ...11 Mounting Mechanical installation 4 Dimensions VS30 1 1 kW 2 2 kW All dimensions in mm ...