To alter the parameters move the asterisk (*) to the
appropriate parameter using the
and
keys, then scroll
through the available settings (shown above) using the
MENU
key.
UART 0 is for input on the Power I/O Port (White) and
Serial - (Green) Input. UART 1 is for Input on the External GPS
Port, GPS Serial Input + (White) and Ground 0V (Grey).
Set the parameters to those that match the navigation receiver
and return to the Input Data Display Test to confirm that the
data is correct. These settings are only used in the Input Data
Display Test and are ignored by the Chartnav in its normal
operation. It may be necessary to experiment with the input
parameters to determine exactly what format your receiver is
providing.
STANDARD INPUT PARAMETERS
Baud RateWord Length Parity
Polarity
C-net NMEA Data
4800
8-bit
None
Normal
NMEA 0183
4800
8-bit
None
Normal
NMEA 0182
1200
8-bit
Even
Normal
Furuno CIF
4800
7-bit
Even
Normal
Koden 757
4800
8-bit
None
Inverse
Koden 717
4800
8-bit
None
Inverse
II Morrow
1200
7-bit
None
Normal
Navstar 2000D
110
8-bit
None
Normal
(The Diagnostic Tests are unable to display the Navstar 2000D input
parameters).
17.4 C-Card Test
Allows you to check the CF95 Chart Cards when you select
this test a new menu will appear.
To do the test move the asterisk (*) to the C-Card Box with the
or
keys and press the
MENU
key.
All manuals and user guides at all-guides.com
all-guides.com
Содержание Chartnav 343
Страница 1: ...Chartnav343 User sGuide Issue03 All manuals and user guides at all guides com a l l g u i d e s c o m ...
Страница 34: ...CHARTNAV343 34 All manuals and user guides at all guides com ...
Страница 46: ...CHARTNAV343 46 All manuals and user guides at all guides com a l l g u i d e s c o m ...