User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 791 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
2006
pwe3-pwc-s-pw-
lic-host-comm-
disrupt
Alarm Equipment
No communication with
TDM-LIC
Major
System malfunction
Reset the TDM-LIC.
2007
pwe3-pws-s-jitter-
buffer-overrun
Alarm Equipment
Jitter-buffer-overrun
alarm on TDM service
Major
Something wrong on
TDM service
synchronization
Check TDM service
configuration
2008
pwe3-pws-s-late-
frame
Alarm Equipment
Late-frame alarm on
TDM service
Warning
Something wrong on
TDM service
Check TDM service
configuration
2009
pwe3-pws-s-loss-
of-frames
Alarm Equipment
Loss-of-frames alarm on
TDM service
Major
Failure along the network
path of TDM service
Check network or configuration
for errors in the network
transport side of the service
2010
pwe3-pws-s-
malformed-frames
Alarm Equipment
Malformed-frames
alarm on TDM service
Major
1.
Payload size does not
correspond to the
defined value.
2.
Mismatch in PT value
in RTP header (if
used)
Check TDM service
configuration
2011
pwe3-pws-s-
misconnection
Alarm Equipment
Misconnection alarm on
TDM service
Major
Stray packets with wrong
RTP configurations are
received and dropped.
Check TDM service
configuration
2012
pwe3-tdm-port-s-
ais
Alarm Equipment
Alarm Indication Signal
(AIS) on TDM-LIC TDM
port
Major
1.
Line is not properly
connected.
2.
External equipment
is faulty.
1.
Reconnect line.
2.
Check line cables.
3.
Check external equipment.