User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 591 of 825
Ceragon Proprietary and Confidential
The following command sets the preamble for GbE 1 to 8:
eth type eth [1/1]>preamble set 8
The following command displays the current preamble for GbE 1:
eth type eth [1/1]>preamble get
17.3.9
Adding a Description for the Interface (CLI)
You can add a text description for an interface. To add a description, go to
interface view for the interface and enter the following command:
eth type eth [x/x]>description set <description>
To delete a description, go to interface view for the interface and enter the
following command:
eth type eth [x/x]>description delete
To display an interface’s description, go to interface view for the interface and
enter the following command:
eth type eth [x/x]>description show
Table 160: Interface Description CLI Parameters
Parameter
Input Type
Permitted Values
Description
description
Text String
Up to 40
characters
Adds a text description to the interface.
The following command adds the description “Line” to GbE 1:
eth type eth [1/1]>description set Line
17.3.10
Displaying Interface Statistics (RMON) (CLI)
IP-20 stores and displays statistics in accordance with RMON and RMON2
standards.
To display RMON statistics for a physical interface, go to interface view for the
interface and enter the following command:
eth type eth [x/x]>rmon statistics show clear-on-read <clear-
on-read> layer-1 <layer-1>
Table 161: Interface Statistics (RMON) CLI Parameters
Parameter
Input Type
Permitted Values
Description
clear-on-read
Boolean
yes
no
If you enter yes, the statistics are cleared
once you display them.
layer-1
Boolean
yes
no
yes
–
Statistics are represented as Layer 1
statistics, including preamble and IFG.
no
–
Statistics are represented as Layer 2
statistics.
The following commands enter interface view for GbE 1, and clear the statistics
after displaying them.