If the Sync mode is set to pipe, you must set it to automatic by entering the
following CLI command in root view:
root> platform sync mode set automatic
When configuring an Ethernet interface as a Sync source, the Media Type of the
interface must be rj45 or sfp,
not
auto-type. To view and configure the Media
Type of an Ethernet interface, see
This section includes:
•
Configuring an Ethernet Interface as a Synchronization Source (CLI)
•
Configuring a Radio Interface as a Synchronization Source (CLI)
•
Clearing All Sync Sources (CLI)
20.3.1
Configuring an Ethernet Interface as a Synchronization Source (CLI)
Note:
In order to select an Ethernet interface, you must first specify the
media type for this interface. See
Configuring Ethernet Interfaces (CLI)
To configure an Ethernet interface as a synchronization source, enter the
following command in root view:
root> platform sync source add eth-interface slot <slot> port
<port> priority <priority> quality <quality>
To edit the parameters of an existing Ethernet interface synchronization source,
enter the following command in root view:
root> platform sync source edit eth-interface slot <slot> port
<port> priority <priority> quality <quality>
To remove an Ethernet interface as a synchronization source, enter the following
command in root view:
root> platform sync source remove eth-interface slot <slot>
port <port>
Table 214: Sync Source Ethernet CLI Parameters
Parameter
Input Type
Permitted Values
Description
slot
Number
1
port
Number
1-3 (IP-20E only)
The interface to be configured as a
synchronization source.
priority
Number
1
–
16
The priority of this synchronization source
relative to other synchronization sources
configured in the unit.