User Guide for FibeAir® IP-20 All-Outdoor Products, CeraOS 10.5
Page 770 of 825
Ceragon Proprietary and Confidential
Alarm ID
Name
Type
Group
Description
Severity
Probable Cause
Corrective Action
1002
radio-protection-
configuration-
mismatch
Alarm Equipment
Radio protection
configuration mismatch
Major
The configuration
between the radio
protection members is
not aligned
Apply a copy-to-mate
command to copy the
configuration from the
required radio to the other one
1006
radio-protection-
switchover-event
Event
Equipment
Radio protection
switchover - reason
Warning
Protection decision
machine initiated
switchover due to local
failure or user command
Check the system for local
failures
1007
radio-protection-
no-mate
Alarm Equipment
Radio protection no
mate
Major
Radio protection function
is missing radio module,
module defected or
disabled
1.
Add radio module.
2.
Replace a defective
existing radio module.
3.
Make sure all radio
interfaces are enabled.
1008
radio-protection-
remote-switch-
request
Event
Equipment
Remote switchover
request was sent -
reason
Warning
1009
radio-protection-
lockout
Alarm Equipment
Radio protection
lockout command is on
Major
The user has issued a
lockout command
Clear the lockout command
1010
ethernet-
protection-
switchover
Event
Equipment
Ethernet Interface
Group protection
switchover
Warning
1.
LOC event on an
Ethernet interface.
2.
Protection group
member was
disabled or pulled
out of the shelf.
1.
Check the system for local
failures.
2.
Check external equipment.