STD ELECTRIC BUTTERFLY VALVE
1.
DEFINITION
Butterfly valve electrically actuated for isolating the flow in fluid handling systems.
The valve installation is compatible with ISO/DIN, BSi, ANSI and JIS installation standards (adapted to different flange
configurations).
Valve design based on Standard EN ISO 16136.
Actuator design based on ISO5211 - DIN3337 (valve connection), EN 60204 (safety), EN 50081-1 / EN 50082-1 / EN 50082-2 / EN
61000-4-2 / EN 61000-4-3 / EN 61000-4-4 / EN 61000-4-5 / EN 61000-4-6 / EN 61000-4-11 (electromagnetic compatibility).
The valve is available with PVC-U disc and body and EPDM sealing gasket.
The electric actuator controls the positions of the valve (closed / open). It is based on a quarter turn operation (90º), it works in
multivoltage power (24-230 VAC/VDC) and it has a protection of IP67.
2.
COMPONENTS
N
DESCRIPTION
1
Butterfly valve
2
Actuation kit
3
Electric actuator
Fig. 1
1
2
3
3.
DIMENSIONS
Verify the valve dimensions before starting the installation.
DN
D
B
E
E’
F
H
K
M
N
L
HOLES
65
63-75 - 2
½
”
135
81
150
18
48
125-145
169
110
181
4
80
90 - 3”
122
95
166
19
52
150-170
169
110
181
4
100
110 - 4”
145
106
178
19
59
180-192
196
110
181
4
125
125-140 - 5”
175
119
194
22
66
190-215
196
110
181
4
150
160 - 6”
209
133
210
24
72
240
254
214
235
4
200
200-225 - 8”
248
161
260
23
73
270-298
254
214
235
4
250
250-280 - 10”
400
199
283
29
114
355-362
254
214
235
12
300
315 - 12”
476
238
330
29
114
390-432
254
214
235
12
Fig. 2
1.1 VERICATION OF VALVE TYPE
On opening the packaging please check that the actuated valve is the model ordered (check the code with the Cepex catalogue).
Make especially sure that the voltage indicated on the actuator label corresponds to that of your main supply (incorrect voltage will
cause irreparable damage to the device).
All valves are electrically and hydraulically tested in the factory. Valves will always be replaced in the event of any justifiable claim.
For more technical information about the actuators, please refer to the instruction manuals attached to the valve documentation.
1.2 GUARANTEE
This equipment has been extensively tested in the factory, thus guaranteeing it works well in Cepex recommended working
conditions (as specified in the Cepex technical catalogue or in the valve Datasheet). This guarantee will be applicable assuming the
device has been properly installed and not used in an incorrect way. For this reason, this equipment must be installed by a qualified
person.
Valve design
Flanged dimensions
Valve connections
Other connections
Actuator coupling
ISO 16136
EN 558-1,ANSI B16.5 Class 150,JIS B2220, BS/E
EN 1090-1
ISO15494, ISO15493, ISO10931
EN/ISO 5211
T 2.2