page 13
www.CentSys.com
S
ECTION
3
S
PECIFICA
TIONS
3.6. Allowable Gate Mass
Ensure that the gate leaf meets Wind Load Specifications
Gate
swing
angle
Up to
1.5m
Up to
2m
Up to
2.5m
Up to
3m
1
Up to
3.5m
1
Up to
4m
1
90°
500kg
500kg
500kg
360kg
260kg
200kg
100°
500kg
500kg
388kg
160kg
190kg
150kg
110°
500kg
306kg
198kg
130kg
120°
180kg
100kg
65kg
Not recommended
TABLE 4
1. An electric lock must be fitted to secure gate in closed position
Gate
swing
angle
Up to
1.5m
Up to
2m
Up to
2.5m
Up to
3m
1
Up to
3.5m
1
Up to
4m
1
90°
750kg
750kg
750kg
550kg
410kg
310kg
100°
750kg
750kg
600kg
420kg
310kg
230kg
110°
750kg
500kg
320kg
220kg
120°
310kg
170kg
110kg
Not recommended
Maximum allowable gate mass for the
VANTAGE 500
operator
TABLE 5
1. An electric lock must be fitted to secure gate in closed position
Maximum allowable gate mass for the
VANTAGE 400
operator